c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,138 kWh
280 cooling + 1,858 heating
Estimated running cost
$706 / year
$59 / month Β· $7,055 over 10 years
Capacity
5.3 kW cooling
5.8 kW heating

13% less electricity than the median of 38 comparable 5 kW reverse cycle ducted split system registrations (2,470 kWh a year) in the cold zone. Uses less than 90% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 74% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,138$706$7,055
Mixed zone 1,122$370$3,703
Hot zone 1,344$444$4,435

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAV50CV1 / FBA50BAVMA6 kW heating5 kW cooling789 kWh/yr0$260
Toshiba RAV-GP561ATP-A1/RAV-GM561DTP-A15.6 kW heating5 kW cooling2,032 kWh/yr3$671

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QSM053D8S/42QSM053D8S5.7 kW heating5.3 kW cooling2,338 kWh/yr3.5$772
Samsung Electronics AC052TXAPKG/SA / AC052TNHDKG/SA6 kW heating5.2 kW cooling2,500 kWh/yr2.5$825
Fujitsu AOTG18LACC/ARTG18LLTA6 kW heating5.2 kW cooling2,536 kWh/yr2.5$837
Tosot TFH18KBXE-S6DNK2D/O / TFH18KBXE-S6DNK2D/I5.7 kW heating5.1 kW cooling2,426 kWh/yr3$801
Daikin RZAV50CBV1 / FBA50BAVMA6 kW heating5 kW cooling2,271 kWh/yr2$749
Toshiba RAV-GP561ATP-A1/RAV-GM561DTP-A15.6 kW heating5 kW cooling2,032 kWh/yr3$671
Daikin RZAV50CV1 / FBA50BAVMA6 kW heating5 kW cooling789 kWh/yr0$260
Toshiba RAV-GM561ATP-A1/RAV-GM561DTP-A15.3 kW heating5 kW cooling2,206 kWh/yr3$728

Compare GUD50W1/NhC-S / GUD50PHS1/C-S with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
5.30 kW
Cooling power input
1.25 kW
Rated heating capacity (7 Β°C)
5.80 kW
Heating power input
1.25 kW
EER, full load (tested)
4.40
COP, full load (tested)
4.65
Rated AEER
4.16
Rated ACOP
4.55
Standby power (PIA)
7.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––390605
Coldresidential3.52.52801,858
Mixedcommercial––575321
Mixedresidential3.53.0422700
Hotcommercial––1,55276
Hotresidential4.03.51,229115
Part-load test points (25 values)
c__t1_min_cap_power_rated
590 W
h__h1_min_cap_power_rated
370 W
h__h2_ext_cap_power_rated
2000 W
c__t1_half_cap_power_rated
550 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
540 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1900 W
h__h2_ext_cap_heat_cap_rated
5700 W
h__h1_half_cap_heat_cap_rated
2870 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
370 W
c__t1_min_cap_cooling_cap_rated
2400 W
c__low_temp_full_cap_power_rated
1142.5 W
c__low_temp_half_cap_power_rated
502.70000000000005 W
c__t1_half_cap_cooling_cap_rated
2650 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
2500 W
c__low_temp_full_cap_cooling_cap_rated
5708.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
2854.0499999999997 W

New Zealand E3 registration details

Registration number
AAC8028
GEMS registration id
159393
Status
approved, available (self-reported)
Registration expires
31 January 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.