c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
2,044 kWh
252 cooling + 1,792 heating
Estimated running cost
$675 / year
$56 / month Β· $6,745 over 10 years
Capacity
5.3 kW cooling
5.8 kW heating

5% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 76% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 76% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree GUD50W1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,044$675$6,745
Mixed zone 1,033$341$3,409
Hot zone 1,216$401$4,013

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Solar Acdc DGWA1-ACDC-18KR25 kW heating5 kW cooling1,905 kWh/yr3.5$629
Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639

Heat pumps similar to the Gree GUD50W1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Fujitsu AOTG18LACC/AUTG18LVLA6 kW heating5.2 kW cooling2,732 kWh/yr2.5$902
Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Bonaire STH053S1AE/STH053S1AI5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/U*5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/UD5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Hyundai HYSSSAC53T*5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639

Other Gree models of similar capacity

ModelStarsEst. cost / yrCompare
Gree GUD50W1/NhC-S / GUD50T1/C-S5.8 kW heating5.3 kW cooling2,045 kWh/yr4$675

Compare GUD50W1/NhC-S / GUD50T1/C-S with another model

Gree GUD50W1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
5.30 kW
Cooling power input
1.25 kW
Rated heating capacity (7 Β°C)
5.80 kW
Heating power input
1.25 kW
EER, full load (tested)
4.32
COP, full load (tested)
4.83
Rated AEER
4.16
Rated ACOP
4.55
Standby power (PIA)
7.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
60.4 dB(A)
Outdoor sound power
66.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree GUD50W1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––346566
Coldresidential4.02.52521,792
Mixedcommercial––531292
Mixedresidential4.03.5384649
Hotcommercial––1,45969
Hotresidential4.54.01,112104
Part-load test points (25 values)
c__t1_min_cap_power_rated
600 W
h__h1_min_cap_power_rated
340 W
h__h2_ext_cap_power_rated
2000 W
c__t1_half_cap_power_rated
470 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
480 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2000 W
h__h2_ext_cap_heat_cap_rated
5500 W
h__h1_half_cap_heat_cap_rated
2900 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
365 W
c__t1_min_cap_cooling_cap_rated
2200 W
c__low_temp_full_cap_power_rated
1142.5 W
c__low_temp_half_cap_power_rated
429.58000000000004 W
c__t1_half_cap_cooling_cap_rated
2650 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
2800 W
c__low_temp_full_cap_cooling_cap_rated
5708.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
2854.0499999999997 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
GUD50W1/NhC-S / GUD50T1/C-SAAC773242,045

New Zealand E3 registration details

Registration number
AAC8026
GEMS registration id
159394
Status
approved, available (self-reported)
Registration expires
29 January 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.