c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,288 kWh
373 cooling + 2,915 heating
Estimated running cost
$1,085 / year
$90 / month Β· $10,850 over 10 years
Capacity
7.1 kW cooling
8 kW heating

About the same electricity as the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,279 kWh a year) in the cold zone. Uses less than 48% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 57% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,288$1,085$10,850
Mixed zone 1,607$530$5,303
Hot zone 1,862$614$6,145

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr3$882
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Aurora AU-BS24HR-2A-O / AU-LCF24-2A-I7.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Mdv C-UV-74N8-QC3W / CDV-74A6N8-QC3W7.5 kW heating7.4 kW cooling2,744 kWh/yr3.5$906
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,756 kWh/yr3$909

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hyundai HYDCTAC71TB7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Panasonic U-71PZH3R5 / S-71PE4R8 kW heating7.1 kW cooling3,014 kWh/yr3$995
Daikin RZAS71C2V1 / FDYA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr3$981
Hyundai HYDCTAC71TC7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Panasonic U-71PZ4R5 / S-71PE4R7.1 kW heating7.1 kW cooling2,870 kWh/yr2.5$947
Daikin RZAS71C2V1 / FDYUA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr3$981
Tosot TFH24ACXF-S6DNE3D/O / TFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr3$1,032
TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914

Compare GUD71W1/NhC-S / GUD71PHS1/C-S with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
1.97 kW
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
2.00 kW
EER, full load (tested)
3.74
COP, full load (tested)
4.03
Rated AEER
3.56
Rated ACOP
3.95
Standby power (PIA)
7.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
67.9 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––512918
Coldresidential3.52.03732,915
Mixedcommercial––770445
Mixedresidential3.52.55791,028
Hotcommercial––2,14097
Hotresidential3.53.51,713149
Part-load test points (25 values)
c__t1_min_cap_power_rated
610 W
h__h1_min_cap_power_rated
370 W
h__h2_ext_cap_power_rated
2060 W
c__t1_half_cap_power_rated
700 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
745 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1900 W
h__h2_ext_cap_heat_cap_rated
6140 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
380 W
c__t1_min_cap_cooling_cap_rated
2350 W
c__low_temp_full_cap_power_rated
1800.5800000000002 W
c__low_temp_half_cap_power_rated
639.8000000000001 W
c__t1_half_cap_cooling_cap_rated
3550 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
2600 W
c__low_temp_full_cap_cooling_cap_rated
7646.7 W
c__low_temp_half_cap_cooling_cap_rated
3823.35 W

New Zealand E3 registration details

Registration number
AAC8025
GEMS registration id
159392
Status
approved, available (self-reported)
Registration expires
29 January 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.