c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
1,316 kWh
150 cooling + 1,166 heating
Estimated running cost
$434 / year
$36 / month Β· $4,343 over 10 years
Capacity
3.5 kW cooling
4 kW heating

6% less electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 69% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 83% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,316$434$4,343
Mixed zone 661$218$2,181
Hot zone 758$250$2,501

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar ACHV35D1S/ASHV35D1S3.8 kW heating3.5 kW cooling1,516 kWh/yr4$500
Kinghome KWH35ATBXB-K6DNA2/O / KWH35ATBXB-K6DNA2/I3.8 kW heating3.5 kW cooling1,516 kWh/yr4$500
Tosot TWH12ATCXB-K6DNA1B/O / TWH12ATCXB-K6DNA3B/I3.8 kW heating3.5 kW cooling1,516 kWh/yr4$500
Hyundai HYSSSAC35TB3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
Kogan KASSSAC35TD3.6 kW heating3.5 kW cooling1,290 kWh/yr4.5$426
TCL TAC-13CHSD/XA72IG3.6 kW heating3.5 kW cooling1,290 kWh/yr4.5$426
TCL TAC-13CHSD/VEIH3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425
Hyundai HYSSSAC35TD3.6 kW heating3.5 kW cooling1,287 kWh/yr4.5$425

Compare GWH12AVDXD-K6DNA1B/O / GWH12AVDXD-K6DNA1B/I with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.52 kW
Cooling power input
0.80 kW
Rated heating capacity (7 Β°C)
4.00 kW
Heating power input
0.86 kW
EER, full load (tested)
4.43
COP, full load (tested)
4.56
Rated AEER
4.37
Rated ACOP
4.63
Standby power (PIA)
1.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
59 dB(A)
Outdoor sound power
63 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––252361
Coldresidential4.52.51501,166
Mixedcommercial––351184
Mixedresidential4.53.5235426
Hotcommercial––86838
Hotresidential5.04.069860
Part-load test points (23 values)
c__t1_min_cap_power_rated
127 W
h__h1_min_cap_power_rated
165 W
h__h2_ext_cap_power_rated
1330 W
c__t1_half_cap_power_rated
325 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
325 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1005 W
h__h2_ext_cap_heat_cap_rated
4000 W
h__h1_half_cap_heat_cap_rated
1965 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
105 W
c__t1_min_cap_cooling_cap_rated
550 W
c__low_temp_half_cap_power_rated
233 W
c__t1_half_cap_cooling_cap_rated
1800 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
900 W
c__low_temp_half_cap_cooling_cap_rated
1700 W

New Zealand E3 registration details

Registration number
AAC9504
GEMS registration id
173736
Status
approved, available (self-reported)
Registration expires
19 October 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.