c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,782 kWh
327 cooling + 2,455 heating
Estimated running cost
$918 / year
$77 / month Β· $9,181 over 10 years
Capacity
6.3 kW cooling
7.4 kW heating

2% more electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 36% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 65% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,782$918$9,181
Mixed zone 1,405$464$4,637
Hot zone 1,611$532$5,316

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling2,078 kWh/yr3.5$686
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling2,082 kWh/yr3.5$687
Daikin RZAV60CV1 / FCTA60AVMA7.1 kW heating6 kW cooling2,191 kWh/yr0$723
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr5$798
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr5$798

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG WS24TWU / WS24TWN7.3 kW heating6.3 kW cooling3,494 kWh/yr3.5$1,153
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Fujitsu AOTG22LVCC/ASTG22LVCC7.2 kW heating6.3 kW cooling3,233 kWh/yr3.5$1,067
Mitsubishi Heavy Industries DXC21ZRA-W / DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Solar Acdc DGWA1-ACDC-24KR27 kW heating6.4 kW cooling2,743 kWh/yr3$905
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862
Comfee CASG-XG60/CASN-XG606.4 kW heating6.1 kW cooling2,645 kWh/yr4.5$873
Mitsubishi Electric MUZ-LN60VG2/MSZ-LN60VGDB6.8 kW heating6.1 kW cooling2,652 kWh/yr3$875

Compare GWH21AGEXF-K6DNA1A/O / GWH21AGEXF-K6DNA1A/I with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
6.30 kW
Cooling power input
1.54 kW
Rated heating capacity (7 Β°C)
7.40 kW
Heating power input
1.80 kW
EER, full load (tested)
4.13
COP, full load (tested)
4.12
Rated AEER
4.03
Rated ACOP
4.05
Standby power (PIA)
6.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61.5 dB(A)
Outdoor sound power
66.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––695769
Coldresidential3.52.03272,455
Mixedcommercial––875396
Mixedresidential3.53.0508897
Hotcommercial––1,97487
Hotresidential4.03.51,477134
Part-load test points (26 values)
h__h1_min_cap_power_rated
370 W
h__h2_ext_cap_power_rated
2700 W
h__h3_ext_cap_power_rated
2700 W
c__t1_half_cap_power_rated
590 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
650 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
Yes
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1940 W
h__h2_ext_cap_heat_cap_rated
6900 W
h__h3_ext_cap_heat_cap_rated
6300 W
h__h1_half_cap_heat_cap_rated
3600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
320 W
c__low_temp_full_cap_power_rated
1409.3880000000001 W
c__low_temp_half_cap_power_rated
539.26 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
3250 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
2100 W
c__low_temp_full_cap_cooling_cap_rated
6785.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
3500.25 W

Other model numbers on registration AAC7506

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7506
GEMS registration id
154187
Status
approved, available (self-reported)
Registration expires
16 May 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
GWH21AGEXF-K6DNA1A/O / GWH21AGEXF-K6DNA1A/I
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.