c/kWh
Energy rating (cooling)
3.5
Heating: 1.5
Annual electricity use
3,494 kWh
331 cooling + 3,163 heating
Estimated running cost
$1,153 / year
$96 / month Β· $11,530 over 10 years
Capacity
6.3 kW cooling
7.3 kW heating

28% more electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 53% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG WS24TWU running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,494$1,153$11,530
Mixed zone 1,655$546$5,462
Hot zone 1,741$575$5,745

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling2,078 kWh/yr3.5$686
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling2,082 kWh/yr3.5$687
Daikin RZAV60CV1 / FCTA60AVMA7.1 kW heating6 kW cooling2,191 kWh/yr0$723
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr5$798
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr5$798

Heat pumps similar to the LG WS24TWU

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Fujitsu AOTG22LVCC/ASTG22LVCC7.2 kW heating6.3 kW cooling3,233 kWh/yr3.5$1,067
Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Gree GWH21AGEXF-K6DNA1A/O / GWH21AGEXF-K6DNA2A/I7.4 kW heating6.3 kW cooling2,782 kWh/yr3.5$918
Gree GWH21AGEXF-K6DNA1A/O / GWH21QEXF-K6DNC8A/I7.4 kW heating6.3 kW cooling2,782 kWh/yr3.5$918
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Solar Acdc DGWA1-ACDC-24KR27 kW heating6.4 kW cooling2,743 kWh/yr3$905
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862
Comfee CASG-XG60/CASN-XG606.4 kW heating6.1 kW cooling2,645 kWh/yr4.5$873

Compare WS24TWU / WS24TWN with another model

LG WS24TWU specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
6.30 kW
Cooling power input
1.92 kW
Rated heating capacity (7 Β°C)
7.30 kW
Heating power input
2.23 kW
EER, full load (tested)
3.39
COP, full load (tested)
3.32
Rated AEER
3.27
Rated ACOP
3.26
Standby power (PIA)
1.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62.5 dB(A)
Outdoor sound power
63.3 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
837 Γ— 308 Γ— 189 mm
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG WS24TWU zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5581,001
Coldresidential3.51.53313,163
Mixedcommercial––785485
Mixedresidential3.52.05291,126
Hotcommercial––2,02095
Hotresidential3.52.51,590151
Part-load test points (23 values)
c__t1_min_cap_power_rated
410 W
h__h2_ext_cap_power_rated
2250 W
c__t1_half_cap_power_rated
680 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
810 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5500 W
h__h1_half_cap_heat_cap_rated
3650 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
297 W
c__t1_min_cap_cooling_cap_rated
2000 W
c__low_temp_full_cap_power_rated
1754.88 W
c__low_temp_half_cap_power_rated
572 W
c__t1_half_cap_cooling_cap_rated
3150 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2100 W
c__low_temp_full_cap_cooling_cap_rated
6785.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
3393 W

New Zealand E3 registration details

Registration number
AAC8342
GEMS registration id
162938
Status
approved, available (self-reported)
Registration expires
9 July 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.