New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
LG WS24TWU / WS24TWN Heat Pump
LG WS24TWU / WS24TWN is a 6.3 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8342).
- Energy rating (cooling)
- 3.5
- Heating: 1.5
- Annual electricity use
- 3,494 kWh
- 331 cooling + 3,163 heating
- Estimated running cost
- $1,153 / year
- $96 / month Β· $11,530 over 10 years
- Capacity
- 6.3 kW cooling
- 7.3 kW heating
28% more electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 0% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 53% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
LG WS24TWU running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,494 | $1,153 | $11,530 |
| Mixed zone | 1,655 | $546 | $5,462 |
| Hot zone | 1,741 | $575 | $5,745 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 6.3 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling2,078 kWh/yr | 3.5 | $686 | |
| Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling2,082 kWh/yr | 3.5 | $687 | |
| Daikin RZAV60CV1 / FCTA60AVMA7.1 kW heating6 kW cooling2,191 kWh/yr | 0 | $723 | |
| Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr | 5 | $798 | |
| Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr | 5 | $798 |
Heat pumps similar to the LG WS24TWU
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTG22LVCC/ASTG22LVCC7.2 kW heating6.3 kW cooling3,233 kWh/yr | 3.5 | $1,067 | |
| Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr | 4 | $827 | |
| Gree GWH21AGEXF-K6DNA1A/O / GWH21AGEXF-K6DNA2A/I7.4 kW heating6.3 kW cooling2,782 kWh/yr | 3.5 | $918 | |
| Gree GWH21AGEXF-K6DNA1A/O / GWH21QEXF-K6DNC8A/I7.4 kW heating6.3 kW cooling2,782 kWh/yr | 3.5 | $918 | |
| Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr | 4 | $827 | |
| Solar Acdc DGWA1-ACDC-24KR27 kW heating6.4 kW cooling2,743 kWh/yr | 3 | $905 | |
| Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr | 5 | $862 | |
| Comfee CASG-XG60/CASN-XG606.4 kW heating6.1 kW cooling2,645 kWh/yr | 4.5 | $873 |
Compare WS24TWU / WS24TWN with another model
LG WS24TWU specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.30 kW
- Cooling power input
- 1.92 kW
- Rated heating capacity (7 Β°C)
- 7.30 kW
- Heating power input
- 2.23 kW
- EER, full load (tested)
- 3.39
- COP, full load (tested)
- 3.32
- Rated AEER
- 3.27
- Rated ACOP
- 3.26
- Standby power (PIA)
- 1.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 62.5 dB(A)
- Outdoor sound power
- 63.3 dB(A)
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 837 Γ 308 Γ 189 mm
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
LG WS24TWU zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 558 | 1,001 |
| Coldresidential | residential | 3.5 | 1.5 | 331 | 3,163 |
| Mixedcommercial | commercial | β | β | 785 | 485 |
| Mixedresidential | residential | 3.5 | 2.0 | 529 | 1,126 |
| Hotcommercial | commercial | β | β | 2,020 | 95 |
| Hotresidential | residential | 3.5 | 2.5 | 1,590 | 151 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 410 W
- h__h2_ext_cap_power_rated
- 2250 W
- c__t1_half_cap_power_rated
- 680 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 810 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 5500 W
- h__h1_half_cap_heat_cap_rated
- 3650 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 297 W
- c__t1_min_cap_cooling_cap_rated
- 2000 W
- c__low_temp_full_cap_power_rated
- 1754.88 W
- c__low_temp_half_cap_power_rated
- 572 W
- c__t1_half_cap_cooling_cap_rated
- 3150 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2100 W
- c__low_temp_full_cap_cooling_cap_rated
- 6785.099999999999 W
- c__low_temp_half_cap_cooling_cap_rated
- 3393 W
New Zealand E3 registration details
- Registration number
- AAC8342
- GEMS registration id
- 162938
- Status
- approved, available (self-reported)
- Registration expires
- 9 July 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.