New Zealand Β· costs in NZD

Cooling only split system air conditioner, wall hung
Haier 1U25YAMCRA / AS25TBMCRA Heat Pump
Haier 1U25YAMCRA / AS25TBMCRA is a 2.5 kW cooling only split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8251).
- Energy rating (cooling)
- 3
- Annual electricity use
- 140 kWh
- Estimated running cost
- $46 / year
- $4 / month Β· $462 over 10 years
- Capacity
- 2.5 kW cooling
14% more electricity than the median of 17 comparable 2.5 kW cooling only split system registrations (123 kWh a year) in the cold zone. Uses less than 18% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 99% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Haier 1U25YAMCRA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 140 | $46 | $462 |
| Mixed zone | 219 | $72 | $723 |
| Hot zone | 643 | $212 | $2,122 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi RAC-DJ25PCAT/RAK-DJ25PCAT2.5 kW cooling90 kWh/yr | 6 | $30 | |
| Daikin RKM25QVMA / FTKM25QVMA2.5 kW cooling93 kWh/yr | 5.5 | $31 | |
| Daikin RKM25Q2VMA / FTKM25Q2VMA2.5 kW cooling95 kWh/yr | 5.5 | $31 | |
| Mitsubishi Heavy Industries SRC10YTA-W/SRK10YTA-WF2.5 kW cooling98 kWh/yr | 5 | $32 | |
| Fujitsu AOTH09CNCA/ASTH09CNCA2.5 kW cooling107 kWh/yr | 4.5 | $35 |
Heat pumps similar to the Haier 1U25YAMCRA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RKM25QVMA / FTKM25QVMA2.5 kW cooling93 kWh/yr | 5.5 | $31 | |
| Fujitsu AOTH09CNCA/ASTH09CNCA2.5 kW cooling107 kWh/yr | 4.5 | $35 | |
| Mitsubishi Electric MUY-GW25VFD/MSY-GW25VFD22.5 kW cooling120 kWh/yr | 3.5 | $40 | |
| Mitsubishi Electric MUY-GW25VFD2/MSY-GW25VFD2 Series2.5 kW cooling120 kWh/yr | 3.5 | $40 | |
| Hitachi RAC-DJ25PCAT/RAK-DJ25PCAT2.5 kW cooling90 kWh/yr | 6 | $30 | |
| Mitsubishi Heavy Industries SRC10YTA-W/SRK10YTA-WF2.5 kW cooling98 kWh/yr | 5 | $32 | |
| Daikin RKM25Q2VMA / FTKM25Q2VMA2.5 kW cooling95 kWh/yr | 5.5 | $31 | |
| Mitsubishi Heavy Industries SRC10YSA-W/SRK10YSA-WF12.5 kW cooling112 kWh/yr | 4 | $37 |
Compare 1U25YAMCRA / AS25TBMCRA with another model
Haier 1U25YAMCRA specifications
- Type
- Cooling only
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.50 kW
- Cooling power input
- 0.65 kW
- Rated heating capacity (7 Β°C)
- β
- Heating power input
- β
- EER, full load (tested)
- 3.97
- COP, full load (tested)
- β
- Rated AEER
- 3.82
- Rated ACOP
- β
- Standby power (PIA)
- 1.5 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 57.3 dB(A)
- Outdoor sound power
- 59.8 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Haier 1U25YAMCRA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 310 | β |
| Coldresidential | residential | 3.0 | β | 140 | β |
| Mixedcommercial | commercial | β | β | 390 | β |
| Mixedresidential | residential | 3.0 | β | 219 | β |
| Hotcommercial | commercial | β | β | 865 | β |
| Hotresidential | residential | 3.5 | β | 643 | β |
Part-load test points (9 values)
- c__t1_half_cap_power_rated
- 250 W
- c__t1_have_min_cap_results
- No
- c__low_temp_full_cap_power_rated
- 594.1 W
- c__low_temp_half_cap_power_rated
- 228.5 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 1250 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 2692.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 1346.25 W
New Zealand E3 registration details
- Registration number
- AAC8251
- GEMS registration id
- 161825
- Status
- approved, available (self-reported)
- Registration expires
- 20 May 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: haierhome.com.au. How the derived figures are calculated.