New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Hisense AUW-160U4RH1/AUD-160UX4RSH1 Heat Pump
Hisense AUW-160U4RH1/AUD-160UX4RSH1 is a 16 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8072).
- Energy rating (cooling)
- 3
- Heating: 1.5
- Annual electricity use
- 8,181 kWh
- 958 cooling + 7,223 heating
- Estimated running cost
- $2,700 / year
- $225 / month Β· $26,997 over 10 years
- Capacity
- 16 kW cooling
- 18.9 kW heating
3% more electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (7,959 kWh a year) in the cold zone. Uses less than 39% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 18% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hisense AUW-160U4RH1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 8,181 | $2,700 | $26,997 |
| Mixed zone | 4,079 | $1,346 | $13,461 |
| Hot zone | 4,808 | $1,587 | $15,866 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 16 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr | 2 | $1,483 | |
| Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling6,561 kWh/yr | 2.5 | $2,165 | |
| Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling6,561 kWh/yr | 2.5 | $2,165 | |
| Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr | 3.5 | $2,279 | |
| Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling6,926 kWh/yr | 3 | $2,286 |
Heat pumps similar to the Hisense AUW-160U4RH1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Gree GUD160W1/NhC-S / GUD160PHS1/C-S18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 | |
| Braemar KCHB160D1B/KDHB160D1S18 kW heating16 kW cooling7,460 kWh/yr | 3.5 | $2,462 | |
| Braemar KCHA160D1B/KDHA160D1S18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 | |
| TECO TDS-TSO160HVSWDG18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 | |
| Panasonic U-160PZH3R8 / S-160PE4RA18 kW heating16 kW cooling7,357 kWh/yr | 2.5 | $2,428 | |
| Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA218 kW heating16 kW cooling7,459 kWh/yr | 3 | $2,461 | |
| Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA2-UF18 kW heating16 kW cooling7,459 kWh/yr | 3 | $2,461 | |
| Panasonic U-160PZH3R5 / S-160PE4RN18 kW heating16 kW cooling7,357 kWh/yr | 2.5 | $2,428 |
Compare AUW-160U4RH1/AUD-160UX4RSH1 with another model
Hisense AUW-160U4RH1 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 16.00 kW
- Cooling power input
- 4.78 kW
- Rated heating capacity (7 Β°C)
- 18.90 kW
- Heating power input
- 4.87 kW
- EER, full load (tested)
- 3.35
- COP, full load (tested)
- 3.86
- Rated AEER
- 3.33
- Rated ACOP
- 3.85
- Standby power (PIA)
- 10.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hisense AUW-160U4RH1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 2,093 | 2,301 |
| Coldresidential | residential | 3.0 | 1.5 | 958 | 7,223 |
| Mixedcommercial | commercial | β | β | 2,649 | 1,159 |
| Mixedresidential | residential | 2.5 | 2.5 | 1,513 | 2,566 |
| Hotcommercial | commercial | β | β | 5,943 | 233 |
| Hotresidential | residential | 3.0 | 3.0 | 4,444 | 364 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 4110 W
- c__t1_half_cap_power_rated
- 1660 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1857 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 13500 W
- h__h1_half_cap_heat_cap_rated
- 9450 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 4365.264 W
- c__low_temp_half_cap_power_rated
- 1517.24 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 8000 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 17232 W
- c__low_temp_half_cap_cooling_cap_rated
- 8616 W
New Zealand E3 registration details
- Registration number
- AAC8072
- GEMS registration id
- 159517
- Status
- approved, available (self-reported)
- Registration expires
- 26 February 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: global.hisense.com. How the derived figures are calculated.