c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
3,696 kWh
422 cooling + 3,274 heating
Estimated running cost
$1,220 / year
$102 / month Β· $12,197 over 10 years
Capacity
7.3 kW cooling
8.3 kW heating

18% more electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 3% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 50% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hisense AUW-71U4RB1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,696$1,220$12,197
Mixed zone 1,869$617$6,168
Hot zone 2,138$706$7,055

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Midea UCMI70OB/CASMI70IB7.7 kW heating7 kW cooling2,745 kWh/yr3$906

Heat pumps similar to the Hisense AUW-71U4RB1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi PAS-3.0UFASNQ1 / PCI-3.0UFA1NQ8.6 kW heating7.2 kW cooling3,499 kWh/yr3.5$1,155
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr4$906
Mitsubishi Electric PUZ-ZM71VHA-A/PLA-M71EA2-A8 kW heating7.1 kW cooling3,086 kWh/yr2.5$1,018
Mitsubishi Electric PUZ-ZM71VHA2-A/PLA-M71EA2-A8 kW heating7.1 kW cooling3,086 kWh/yr2.5$1,018
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr3$875
Fujitsu AOTH24KBTA/AUTH24KRTA8 kW heating7.1 kW cooling3,214 kWh/yr3$1,061
Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr3$879

Compare AUW-71U4RB1/ AUC-71UR4RJC1 with another model

Hisense AUW-71U4RB1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
7.30 kW
Cooling power input
2.21 kW
Rated heating capacity (7 Β°C)
8.30 kW
Heating power input
2.50 kW
EER, full load (tested)
3.48
COP, full load (tested)
3.54
Rated AEER
3.28
Rated ACOP
3.30
Standby power (PIA)
5.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hisense AUW-71U4RB1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––9091,023
Coldresidential3.01.54223,274
Mixedcommercial––1,157525
Mixedresidential2.52.06721,197
Hotcommercial––2,614110
Hotresidential3.02.51,965173
Part-load test points (20 values)
h__h2_ext_cap_power_rated
2650 W
c__t1_half_cap_power_rated
710 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
880 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
7000 W
h__h1_half_cap_heat_cap_rated
4200 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
2019.94 W
c__low_temp_half_cap_power_rated
648.94 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3650 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
7862.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
3931.0499999999997 W

New Zealand E3 registration details

Registration number
AAC7514
GEMS registration id
154291
Status
approved, available (self-reported)
Registration expires
17 May 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.