c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
5,602 kWh
667 cooling + 4,935 heating
Estimated running cost
$1,849 / year
$154 / month Β· $18,487 over 10 years
Capacity
12.5 kW cooling
14 kW heating

6% less electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 62% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,602$1,849$18,487
Mixed zone 2,787$920$9,197
Hot zone 3,281$1,083$10,827

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Hitachi

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Daikin RZAV125FY1 / FCA125CVMA15 kW heating12.5 kW cooling5,137 kWh/yr4$1,695
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657
Fujitsu AOTH45KBTA/AUTH45KRTA14 kW heating12.5 kW cooling5,769 kWh/yr3$1,904
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Fujitsu AOTH45KRTA/AUTH45KRTA14 kW heating12.5 kW cooling5,769 kWh/yr3$1,904

Compare PAS-5.0UFASNQ1 / PCI-5.0UFA1NQ with another model

Hitachi specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.38 kW
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
3.41 kW
EER, full load (tested)
3.63
COP, full load (tested)
4.07
Rated AEER
3.64
Rated ACOP
4.05
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,4171,560
Coldresidential3.52.06674,935
Mixedcommercial––1,798780
Mixedresidential3.02.51,0551,732
Hotcommercial––4,013168
Hotresidential3.53.53,023258
Part-load test points (20 values)
h__h2_ext_cap_power_rated
2800 W
c__t1_half_cap_power_rated
1150 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1200 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
10000 W
h__h1_half_cap_heat_cap_rated
7000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3089.32 W
c__low_temp_half_cap_power_rated
1051.1000000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6600 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
13462.5 W
c__low_temp_half_cap_cooling_cap_rated
7108.2 W

New Zealand E3 registration details

Registration number
AAC7963
GEMS registration id
156497
Status
approved, available (self-reported)
Registration expires
11 December 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.