c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
5,013 kWh
583 cooling + 4,430 heating
Estimated running cost
$1,654 / year
$138 / month Β· $16,543 over 10 years
Capacity
12.5 kW cooling
13 kW heating

16% less electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 90% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KDI42 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,013$1,654$16,543
Mixed zone 2,607$860$8,603
Hot zone 2,831$934$9,342

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528

Heat pumps similar to the Kaden KDI42

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Fujitsu AOTH45KRTA/AUTH45KRTA14 kW heating12.5 kW cooling5,769 kWh/yr3$1,904
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Daikin RZAV125FY1 / FCA125CVMA15 kW heating12.5 kW cooling5,137 kWh/yr4$1,695
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Hitachi PAS-5.0UFASMQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling5,594 kWh/yr3$1,846
Hitachi PAS-5.0UFASNQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling5,602 kWh/yr3.5$1,849

Compare KDI42 / KCI42 with another model

Kaden KDI42 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.39 kW
Rated heating capacity (7 Β°C)
13.00 kW
Heating power input
3.42 kW
EER, full load (tested)
3.69
COP, full load (tested)
3.81
Rated AEER
3.65
Rated ACOP
3.76
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
65 dB(A)
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KDI42 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5531,378
Coldresidential4.02.05834,430
Mixedcommercial––1,093721
Mixedresidential4.02.59261,681
Hotcommercial––2,629156
Hotresidential4.53.02,586245
Part-load test points (25 values)
c__t1_min_cap_power_rated
725 W
h__h1_min_cap_power_rated
540 W
h__h2_ext_cap_power_rated
5780 W
c__t1_half_cap_power_rated
1655 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1240 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2760 W
h__h2_ext_cap_heat_cap_rated
14800 W
h__h1_half_cap_heat_cap_rated
6155 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
460 W
c__t1_min_cap_cooling_cap_rated
3760 W
c__low_temp_full_cap_power_rated
3098.46 W
c__low_temp_half_cap_power_rated
935 W
c__t1_half_cap_cooling_cap_rated
5950 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3720 W
c__low_temp_full_cap_cooling_cap_rated
13462.5 W
c__low_temp_half_cap_cooling_cap_rated
6060 W

New Zealand E3 registration details

Registration number
AAC7200
GEMS registration id
151493
Status
approved, available (self-reported)
Registration expires
5 December 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: reece.com.au. How the derived figures are calculated.