c/kWh
Energy rating (cooling)
3.5
Heating: 1.5
Annual electricity use
4,140 kWh
435 cooling + 3,705 heating
Estimated running cost
$1,366 / year
$114 / month Β· $13,662 over 10 years
Capacity
8 kW cooling
9 kW heating

14% more electricity than the median of 117 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 13% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 46% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi RAC-S80YHAB running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,140$1,366$13,662
Mixed zone 1,959$646$6,465
Hot zone 2,220$733$7,326

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr3$875
Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr3$879
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr4$906
Daikin RXM71AVMA / FTXM71AVMA8 kW heating7.1 kW cooling2,764 kWh/yr3.5$912

Heat pumps similar to the Hitachi RAC-S80YHAB

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 1U80QAFFRA / AS80QFFHRA9 kW heating8 kW cooling3,455 kWh/yr3.5$1,140
Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Carrier 38QRG080N8/42QRG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Solar Acdc DGWA1-ACDCBLW-30KR29 kW heating8 kW cooling3,418 kWh/yr4$1,128
Panasonic CU-RZ80YKR / CS-RZ80YKR9 kW heating8 kW cooling3,422 kWh/yr3.5$1,129
Panasonic CU-RZ80DKR / CS-RZ80DKR9 kW heating8 kW cooling3,422 kWh/yr3.5$1,129
Carrier 38QAG080N8/42QAG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Kogan KASSSAC80HB8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083

Compare RAC-S80YHAB/RAS-S80YHAB with another model

Hitachi RAC-S80YHAB specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
8.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
9.00 kW
Heating power input
–
EER, full load (tested)
3.33
COP, full load (tested)
3.92
Rated AEER
3.25
Rated ACOP
3.78
Standby power (PIA)
3.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62 dB(A)
Outdoor sound power
66 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAC-S80YHAB zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––9391,098
Coldresidential3.51.54353,705
Mixedcommercial––1,205534
Mixedresidential3.02.07031,256
Hotcommercial––2,75092
Hotresidential3.53.52,074146
Part-load test points (20 values)
h__h2_ext_cap_power_rated
1850 W
c__t1_half_cap_power_rated
730 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
750 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5800 W
h__h1_half_cap_heat_cap_rated
4500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
2239.3 W
c__low_temp_half_cap_power_rated
667.22 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
8616 W
c__low_temp_half_cap_cooling_cap_rated
4308 W

New Zealand E3 registration details

Registration number
AAC7593
GEMS registration id
–
Status
approved
Registration expires
26 June 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. Manufacturer: hitachiaircon.com/au. How the derived figures are calculated.