c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
653 kWh
120 cooling + 533 heating
Estimated running cost
$215 / year
$18 / month Β· $2,155 over 10 years
Capacity
2.5 kW cooling
3.5 kW heating

39% less electricity than the median of 178 comparable 2.5 kW reverse cycle split system registrations (1,074 kWh a year) in the cold zone. Uses less than 99% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 93% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi RAC-VJ25NHAE running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 653$215$2,155
Mixed zone 450$149$1,485
Hot zone 426$141$1,406

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the Hitachi RAC-VJ25NHAE

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QRF026N8/42QRF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Daikin RXM25AVMA / FTXM25AVMA3.2 kW heating2.5 kW cooling888 kWh/yr6$293
Kaden KSI-2.52.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HSNRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Pioneer International HPR-09A22.6 kW heating2.5 kW cooling845 kWh/yr4$279

Compare RAC-VJ25NHAE/RAI-VJ25RHAE with another model

Hitachi RAC-VJ25NHAE specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.59 kW
Rated heating capacity (7 Β°C)
3.50 kW
Heating power input
0.88 kW
EER, full load (tested)
4.53
COP, full load (tested)
4.52
Rated AEER
4.15
Rated ACOP
3.97
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Dimensions (WΓ—HΓ—D)
760 Γ— 600 Γ— 235 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAC-VJ25NHAE zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––327355
Coldresidential4.02.5120533
Mixedcommercial––29320
Mixedresidential1.03.0186264
Hotcommercial––26940
Hotresidential4.50.037155
Part-load test points (21 values)
c__t1_min_cap_power_rated
210 W
h__h2_ext_cap_power_rated
1055 W
c__t1_half_cap_power_rated
265 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
300 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3200 W
h__h1_half_cap_heat_cap_rated
1750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
170 W
c__t1_min_cap_cooling_cap_rated
970 W
c__low_temp_half_cap_power_rated
205 W
c__t1_half_cap_cooling_cap_rated
1250 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1250 W
c__low_temp_half_cap_cooling_cap_rated
1350 W

New Zealand E3 registration details

Registration number
AAC10270
GEMS registration id
180414
Status
approved, available (self-reported)
Registration expires
1 July 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.