c/kWh
Energy rating (cooling)
6
Heating: 3.5
Annual electricity use
888 kWh
88 cooling + 800 heating
Estimated running cost
$293 / year
$24 / month Β· $2,930 over 10 years
Capacity
2.5 kW cooling
3.2 kW heating

17% less electricity than the median of 178 comparable 2.5 kW reverse cycle split system registrations (1,074 kWh a year) in the cold zone. Uses less than 88% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 91% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RXM25AVMA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 888$293$2,930
Mixed zone 446$147$1,472
Hot zone 443$146$1,462

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261

Heat pumps similar to the Daikin RXM25AVMA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Pioneer International HPR-09A22.6 kW heating2.5 kW cooling845 kWh/yr4$279
Carrier 42QHG026N8PB/38QUH026N8PB2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Comfee CASG-XG26B/CASN-XG26B2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Kaden KSI-2.52.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HSNRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296

Compare RXM25AVMA / FTXM25AVMA with another model

Daikin RXM25AVMA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.47 kW
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
0.57 kW
EER, full load (tested)
5.40
COP, full load (tested)
5.37
Rated AEER
5.27
Rated ACOP
5.57
Standby power (PIA)
1.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
57 dB(A)
Outdoor sound power
59 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RXM25AVMA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––114260
Coldresidential6.03.588800
Mixedcommercial––184139
Mixedresidential5.54.0139307
Hotcommercial––46430
Hotresidential6.54.539746
Part-load test points (23 values)
c__t1_min_cap_power_rated
210 W
h__h1_min_cap_power_rated
159 W
h__h2_ext_cap_power_rated
1500 W
c__t1_half_cap_power_rated
220 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
245 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1000 W
h__h2_ext_cap_heat_cap_rated
4200 W
h__h1_half_cap_heat_cap_rated
1600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
134 W
c__t1_min_cap_cooling_cap_rated
1100 W
c__low_temp_half_cap_power_rated
150 W
c__t1_half_cap_cooling_cap_rated
1250 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1183.3 W
c__low_temp_half_cap_cooling_cap_rated
1347 W

New Zealand E3 registration details

Registration number
AAC10031
GEMS registration id
178274
Status
approved, available (self-reported)
Registration expires
6 April 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8