c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
749 kWh
107 cooling + 642 heating
Estimated running cost
$247 / year
$21 / month Β· $2,472 over 10 years
Capacity
2.1 kW cooling
2.1 kW heating

10% less electricity than the median of 63 comparable 2 kW reverse cycle split system registrations (829 kWh a year) in the cold zone. Uses less than 73% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 92% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hyundai HYSSSAC21T* running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 749$247$2,472
Mixed zone 428$141$1,412
Hot zone 503$166$1,660

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling708 kWh/yr5.5$234
Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling718 kWh/yr5.5$237
Kaden KSI062.3 kW heating2 kW cooling718 kWh/yr5.5$237
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling718 kWh/yr5.5$237
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239

Heat pumps similar to the Hyundai HYSSSAC21T*

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
TCL TAC-08CHSD/TPH11ITU2.1 kW heating2.1 kW cooling749 kWh/yr3.5$247
Midea MFEZ20VA-W/MFEZ20VA-N2.5 kW heating2.1 kW cooling750 kWh/yr5.5$248
Carrier 38QUH020N8L/42QCE020N8P2.5 kW heating2.1 kW cooling750 kWh/yr5.5$248
TCL TAC-08CHSD/*ITU2.1 kW heating2.1 kW cooling749 kWh/yr3.5$247
Carrier 38QUH020N8L/42QCE020N8F2.5 kW heating2.1 kW cooling750 kWh/yr5.5$248
Midea MFEF20VA-W/MFEF20VA-N2.5 kW heating2.1 kW cooling750 kWh/yr5.5$248
Daikin RXM20W1VMA / FTXM20W1VMA2.7 kW heating2.2 kW cooling829 kWh/yr5$274
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239

Compare HYSSSAC21T* with another model

Hyundai HYSSSAC21T* specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.15 kW
Cooling power input
0.52 kW
Rated heating capacity (7 Β°C)
2.10 kW
Heating power input
0.44 kW
EER, full load (tested)
4.23
COP, full load (tested)
4.85
Rated AEER
4.04
Rated ACOP
4.64
Standby power (PIA)
3.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
49.3 dB(A)
Outdoor sound power
63.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hyundai HYSSSAC21T* zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––168220
Coldresidential3.52.5107642
Mixedcommercial––238124
Mixedresidential3.53.0165263
Hotcommercial––55431
Hotresidential4.53.045647
Part-load test points (18 values)
h__h2_ext_cap_power_rated
855 W
c__t1_half_cap_power_rated
220 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
200 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2800 W
h__h1_half_cap_heat_cap_rated
1000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
160 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1050 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1150 W

Other model numbers on registration AAC8904

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC8904
GEMS registration id
169646
Status
approved, available (self-reported)
Registration expires
25 May 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
HYSSSAC21T*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.