c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,736 kWh
349 cooling + 2,387 heating
Estimated running cost
$903 / year
$75 / month Β· $9,029 over 10 years
Capacity
7.3 kW cooling
7.3 kW heating

4% less electricity than the median of 17 comparable 7 kW reverse cycle fixed registrations (2,850 kWh a year) in the cold zone. Uses less than 65% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 66% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KM24 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,736$903$9,029
Mixed zone 1,481$489$4,887
Hot zone 1,666$550$5,498

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air MRC-075CS-37.6 kW heating7.5 kW cooling2,624 kWh/yr4$866
Midea MULMI0371B7.5 kW heating7.1 kW cooling2,636 kWh/yr3.5$870

Heat pumps similar to the Kaden KM24

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
TECO TSOM73HVAG38.3 kW heating7.3 kW cooling3,237 kWh/yr3$1,068
Midea MULMI0373B/MFAG20N7.3 kW heating7.3 kW cooling2,736 kWh/yr3.5$903
Carrier 38QUM071D8S37.4 kW heating7.2 kW cooling2,692 kWh/yr3.5$888
Midea MULMI0371B7.5 kW heating7.1 kW cooling2,636 kWh/yr3.5$870
Mitsubishi Electric MXZ-4F71VGD8 kW heating7.1 kW cooling2,826 kWh/yr3.5$933
Actron Air MRC-075CS-37.6 kW heating7.5 kW cooling2,624 kWh/yr4$866
Actron Air MRC-075DS-37.4 kW heating7.5 kW cooling2,654 kWh/yr4$876

Other Kaden models of similar capacity

ModelStarsEst. cost / yrCompare
Kaden KM7.37.5 kW heating7.3 kW cooling2,753 kWh/yr3.5$908

Compare KM24 with another model

Kaden KM24 specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.30 kW
Cooling power input
2.00 kW
Rated heating capacity (7 Β°C)
7.30 kW
Heating power input
1.72 kW
EER, full load (tested)
3.66
COP, full load (tested)
4.24
Rated AEER
3.58
Rated ACOP
4.15
Standby power (PIA)
12.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KM24 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––286772
Coldresidential3.52.53492,387
Mixedcommercial––604418
Mixedresidential3.52.5550931
Hotcommercial––1,591102
Hotresidential4.53.01,511155
Part-load test points (25 values)
c__t1_min_cap_power_rated
665 W
h__h1_min_cap_power_rated
395 W
h__h2_ext_cap_power_rated
2790 W
c__t1_half_cap_power_rated
815 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
690 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2000 W
h__h2_ext_cap_heat_cap_rated
8000 W
h__h1_half_cap_heat_cap_rated
3420 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
380 W
c__t1_min_cap_cooling_cap_rated
3000 W
c__low_temp_full_cap_power_rated
1828 W
c__low_temp_half_cap_power_rated
500 W
c__t1_half_cap_cooling_cap_rated
3600 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2870 W
c__low_temp_full_cap_cooling_cap_rated
7862.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
3575 W

New Zealand E3 registration details

Registration number
AAC7067
GEMS registration id
149865
Status
approved, available (self-reported)
Registration expires
29 September 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: reece.com.au. How the derived figures are calculated.