New Zealand Β· costs in NZD
Reverse cycle air conditioner
Kaden KM7.3 Heat Pump
Kaden KM7.3 is a 7.3 kW reverse cycle heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10080).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,753 kWh
- 354 cooling + 2,399 heating
- Estimated running cost
- $908 / year
- $76 / month Β· $9,085 over 10 years
- Capacity
- 7.3 kW cooling
- 7.5 kW heating
10% less electricity than the median of 22 comparable 7 kW reverse cycle registrations (3,048 kWh a year) in the cold zone. Uses less than 68% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 66% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kaden KM7.3 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,753 | $908 | $9,085 |
| Mixed zone | 1,496 | $494 | $4,937 |
| Hot zone | 1,705 | $563 | $5,627 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air MRC-075CS-37.6 kW heating7.5 kW cooling2,624 kWh/yr | 4 | $866 | |
| Midea MULMI0371B7.5 kW heating7.1 kW cooling2,636 kWh/yr | 3.5 | $870 | |
| Actron Air MRC-075DS-37.4 kW heating7.5 kW cooling2,654 kWh/yr | 4 | $876 |
Heat pumps similar to the Kaden KM7.3
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TECO TSOM73HVAG38.3 kW heating7.3 kW cooling3,237 kWh/yr | 3 | $1,068 | |
| Midea MULMI0373B/MFAG20N7.3 kW heating7.3 kW cooling2,736 kWh/yr | 3.5 | $903 | |
| Carrier 38QUM071D8S37.4 kW heating7.2 kW cooling2,692 kWh/yr | 3.5 | $888 | |
| Midea MDV-V80WHN8(At)7.2 kW heating7.2 kW cooling3,023 kWh/yr | 2 | $998 | |
| Mitsubishi Electric MXZ-4F71VGD8 kW heating7.1 kW cooling2,826 kWh/yr | 3.5 | $933 | |
| Actron Air MRC-075CS-37.6 kW heating7.5 kW cooling2,624 kWh/yr | 4 | $866 | |
| Actron Air MRC-075DS-37.4 kW heating7.5 kW cooling2,654 kWh/yr | 4 | $876 |
Other Kaden models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KM247.3 kW heating7.3 kW cooling2,736 kWh/yr | 3.5 | $903 |
Compare KM7.3 with another model
Kaden KM7.3 specifications
- Type
- Reverse cycle
- Configuration
- β
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 7.30 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 7.50 kW
- Heating power input
- β
- EER, full load (tested)
- 3.68
- COP, full load (tested)
- 4.58
- Rated AEER
- 3.61
- Rated ACOP
- 4.46
- Standby power (PIA)
- 12.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 65.8 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kaden KM7.3 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 293 | 787 |
| Coldresidential | residential | 3.5 | 2.5 | 354 | 2,399 |
| Mixedcommercial | commercial | β | β | 630 | 428 |
| Mixedresidential | residential | 3.5 | 2.5 | 557 | 939 |
| Hotcommercial | commercial | β | β | 1,695 | 105 |
| Hotresidential | residential | 4.5 | 3.0 | 1,546 | 159 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 668 W
- h__h1_min_cap_power_rated
- 415 W
- h__h2_ext_cap_power_rated
- 2638 W
- c__t1_half_cap_power_rated
- 770 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 700 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2070 W
- h__h2_ext_cap_heat_cap_rated
- 7960 W
- h__h1_half_cap_heat_cap_rated
- 3450 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 384 W
- c__t1_min_cap_cooling_cap_rated
- 3150 W
- c__low_temp_half_cap_power_rated
- 509 W
- c__t1_half_cap_cooling_cap_rated
- 3450 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2850 W
- c__low_temp_half_cap_cooling_cap_rated
- 3600 W
New Zealand E3 registration details
- Registration number
- AAC10080
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 21 April 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- 19
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.