New Zealand Β· costs in NZD
Reverse cycle air conditioner
Kaden KM46 Heat Pump
Kaden KM46 is a 12 kW reverse cycle heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7034).
- Energy rating (cooling)
- 3.5
- Heating: 1.5
- Annual electricity use
- 5,342 kWh
- 622 cooling + 4,720 heating
- Estimated running cost
- $1,763 / year
- $147 / month Β· $17,629 over 10 years
- Capacity
- 12 kW cooling
- 12 kW heating
4% less electricity than the median of 35 comparable 12.5 kW reverse cycle registrations (5,553 kWh a year) in the cold zone. Uses less than 66% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 37% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kaden KM46 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,342 | $1,763 | $17,629 |
| Mixed zone | 2,727 | $900 | $8,999 |
| Hot zone | 3,003 | $991 | $9,910 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 12 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr | 3.5 | $1,440 | |
| Kinghome KWHD(36)NK6PO11.4 kW heating10.6 kW cooling4,364 kWh/yr | 3.5 | $1,440 | |
| Carrier 38QUM110D8S512.5 kW heating11.6 kW cooling4,367 kWh/yr | 3.5 | $1,441 | |
| Daikin RSUYQ4AVMA12.5 kW heating11.2 kW cooling4,422 kWh/yr | 2.5 | $1,459 | |
| Daikin RSUYQ4A2VMA12.5 kW heating11.2 kW cooling4,424 kWh/yr | 2.5 | $1,460 |
Heat pumps similar to the Kaden KM46
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air MMV-120CS14 kW heating12 kW cooling5,818 kWh/yr | 2.5 | $1,920 | |
| Actron Air MMV-120CT14 kW heating12 kW cooling5,818 kWh/yr | 2.5 | $1,920 | |
| Mdv MV8M-120WV2N814 kW heating12 kW cooling5,818 kWh/yr | 2.5 | $1,920 | |
| Midea MV8M-120WV2N814 kW heating12 kW cooling5,818 kWh/yr | 2.5 | $1,920 | |
| Samsung Electronics AJ120HCJ5KG13.5 kW heating12 kW cooling5,605 kWh/yr | 3 | $1,850 | |
| Mdv MV8M-120WV2RN814 kW heating12 kW cooling5,818 kWh/yr | 2.5 | $1,920 | |
| Mitsubishi Electric MXZ-6F120VGD13.2 kW heating12 kW cooling5,394 kWh/yr | 4 | $1,780 | |
| Midea MV8M-120WV2RN814 kW heating12 kW cooling5,818 kWh/yr | 2.5 | $1,920 |
Compare KM46 with another model
Kaden KM46 specifications
- Type
- Reverse cycle
- Configuration
- β
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 12.00 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 12.00 kW
- Heating power input
- β
- EER, full load (tested)
- 3.33
- COP, full load (tested)
- 3.86
- Rated AEER
- 3.32
- Rated ACOP
- 3.73
- Standby power (PIA)
- 19.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 72 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kaden KM46 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 898 | 1,505 |
| Coldresidential | residential | 3.5 | 1.5 | 622 | 4,720 |
| Mixedcommercial | commercial | β | β | 1,350 | 789 |
| Mixedresidential | residential | 3.0 | 2.0 | 989 | 1,738 |
| Hotcommercial | commercial | β | β | 3,077 | 186 |
| Hotresidential | residential | 4.0 | 2.5 | 2,723 | 280 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 560 W
- h__h1_min_cap_power_rated
- 595 W
- h__h2_ext_cap_power_rated
- 3510 W
- c__t1_half_cap_power_rated
- 1395 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1275 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2460 W
- h__h2_ext_cap_heat_cap_rated
- 9620 W
- h__h1_half_cap_heat_cap_rated
- 5850 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 450 W
- c__t1_min_cap_cooling_cap_rated
- 2530 W
- c__low_temp_full_cap_power_rated
- 3244.7 W
- c__low_temp_half_cap_power_rated
- 870 W
- c__t1_half_cap_cooling_cap_rated
- 5770 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3330 W
- c__low_temp_full_cap_cooling_cap_rated
- 12924 W
- c__low_temp_half_cap_cooling_cap_rated
- 5865 W
New Zealand E3 registration details
- Registration number
- AAC7034
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 26 September 2027
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- 20
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.