c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
4,364 kWh
524 cooling + 3,840 heating
Estimated running cost
$1,440 / year
$120 / month Β· $14,401 over 10 years
Capacity
10.6 kW cooling
11.4 kW heating

11% less electricity than the median of 17 comparable 10 kW reverse cycle multi-split / vrf registrations (4,896 kWh a year) in the cold zone. Uses less than 77% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 44% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kinghome KWHD(36)NK6PO running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,364$1,440$14,401
Mixed zone 2,217$732$7,316
Hot zone 2,596$857$8,567

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the Kinghome KWHD(36)NK6PO

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38VS00418SHCSS12.5 kW heating11.2 kW cooling5,107 kWh/yr2.5$1,685
Toshiba MCY-MHP0405HT12.5 kW heating11.2 kW cooling5,107 kWh/yr2.5$1,685
Midea MV8M-100WV2N812 kW heating10 kW cooling5,284 kWh/yr2$1,744
LG 5MXM100MA010.3 kW heating10 kW cooling4,413 kWh/yr3$1,456
Daikin RSUYQ4AVMA12.5 kW heating11.2 kW cooling4,422 kWh/yr2.5$1,459
Daikin RSUYQ4A2VMA12.5 kW heating11.2 kW cooling4,424 kWh/yr2.5$1,460
Mdv MV8M-100WV2N812 kW heating10 kW cooling5,284 kWh/yr2$1,744
Hisense AVW-34HJFAH111.2 kW heating10 kW cooling5,245 kWh/yr3.5$1,731

Compare KWHD(36)NK6PO with another model

Kinghome KWHD(36)NK6PO specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
Floor mounted
Rated cooling capacity (35 Β°C)
10.60 kW
Cooling power input
2.65 kW
Rated heating capacity (7 Β°C)
11.40 kW
Heating power input
2.85 kW
EER, full load (tested)
4.12
COP, full load (tested)
4.18
Rated AEER
3.95
Rated ACOP
3.95
Standby power (PIA)
10.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64.6 dB(A)
Outdoor sound power
69.1 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kinghome KWHD(36)NK6PO zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1131,201
Coldresidential3.52.05243,840
Mixedcommercial––1,412613
Mixedresidential3.53.08271,390
Hotcommercial––3,168136
Hotresidential4.03.52,386210
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3900 W
c__t1_half_cap_power_rated
860 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1000 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
10500 W
h__h1_half_cap_heat_cap_rated
5700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5300 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC10355
GEMS registration id
181250
Status
approved, available (self-reported)
Registration expires
3 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.