New Zealand Β· costs in NZD

Reverse cycle air conditioner
Carrier 38QUM105D8S5 Heat Pump
Carrier 38QUM105D8S5 is a 10.7 kW reverse cycle heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7035).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 4,608 kWh
- 585 cooling + 4,023 heating
- Estimated running cost
- $1,521 / year
- $127 / month Β· $15,206 over 10 years
- Capacity
- 10.7 kW cooling
- 11 kW heating
About the same electricity as the median of 43 comparable 10 kW reverse cycle registrations (4,608 kWh a year) in the cold zone. Uses less than 49% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 42% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Carrier 38QUM105D8S5 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,608 | $1,521 | $15,206 |
| Mixed zone | 2,447 | $808 | $8,075 |
| Hot zone | 2,799 | $924 | $9,237 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10.7 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric MXZ-5F100VGD10 kW heating10 kW cooling3,703 kWh/yr | 3.5 | $1,222 | |
| Fujitsu AOTG36LBLA512 kW heating10 kW cooling4,079 kWh/yr | 3.5 | $1,346 | |
| Fujitsu AOTH36KBTA512 kW heating10 kW cooling4,088 kWh/yr | 4 | $1,349 | |
| Daikin 5MXM100RVMA11 kW heating10 kW cooling4,337 kWh/yr | 3 | $1,431 | |
| TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr | 3.5 | $1,440 |
Heat pumps similar to the Carrier 38QUM105D8S5
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hyundai HYSMHS10OTD12.3 kW heating10.7 kW cooling4,935 kWh/yr | 3 | $1,629 | |
| Bonaire H4M105S2AE12.3 kW heating10.7 kW cooling4,935 kWh/yr | 3 | $1,629 | |
| TCL TFM4-36CHD/DVO12.3 kW heating10.7 kW cooling4,935 kWh/yr | 3 | $1,629 | |
| Hyundai HYSMHS10OTB12.3 kW heating10.7 kW cooling4,935 kWh/yr | 3 | $1,629 | |
| TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr | 3.5 | $1,440 | |
| Midea MULMI0511B11 kW heating10.5 kW cooling4,536 kWh/yr | 3 | $1,497 | |
| Hisense AMW4-100U4RQA/AST-09UW4RMETD0111.1 kW heating10.5 kW cooling4,380 kWh/yr | 3 | $1,445 | |
| Hisense AMW4-100U4RQA11.1 kW heating10.5 kW cooling4,380 kWh/yr | 3 | $1,445 |
Compare 38QUM105D8S5 with another model
Carrier 38QUM105D8S5 specifications
- Type
- Reverse cycle
- Configuration
- β
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.70 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 11.00 kW
- Heating power input
- β
- EER, full load (tested)
- 3.34
- COP, full load (tested)
- 4.05
- Rated AEER
- 3.26
- Rated ACOP
- 3.78
- Standby power (PIA)
- 19.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 67.9 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Carrier 38QUM105D8S5 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 870 | 1,292 |
| Coldresidential | residential | 3.0 | 2.0 | 585 | 4,023 |
| Mixedcommercial | commercial | β | β | 1,285 | 687 |
| Mixedresidential | residential | 3.0 | 2.5 | 923 | 1,524 |
| Hotcommercial | commercial | β | β | 2,940 | 166 |
| Hotresidential | residential | 3.5 | 3.0 | 2,548 | 251 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 559 W
- h__h1_min_cap_power_rated
- 585 W
- h__h2_ext_cap_power_rated
- 3380 W
- c__t1_half_cap_power_rated
- 1325 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1200 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2654 W
- h__h2_ext_cap_heat_cap_rated
- 9860 W
- h__h1_half_cap_heat_cap_rated
- 5603 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 448 W
- c__t1_min_cap_cooling_cap_rated
- 2341 W
- c__low_temp_full_cap_power_rated
- 2943.08 W
- c__low_temp_half_cap_power_rated
- 839 W
- c__t1_half_cap_cooling_cap_rated
- 5710 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3088 W
- c__low_temp_full_cap_cooling_cap_rated
- 11523.9 W
- c__low_temp_half_cap_cooling_cap_rated
- 5463 W
New Zealand E3 registration details
- Registration number
- AAC7035
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 26 September 2027
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- 20
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.