c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
4,935 kWh
590 cooling + 4,345 heating
Estimated running cost
$1,629 / year
$136 / month Β· $16,286 over 10 years
Capacity
10.7 kW cooling
12.3 kW heating

9% more electricity than the median of 26 comparable 10 kW reverse cycle fixed registrations (4,539 kWh a year) in the cold zone. Uses less than 15% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

TCL TFM4-36CHD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,935$1,629$16,286
Mixed zone 2,538$838$8,375
Hot zone 2,898$956$9,563

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MXZ-5F100VGD10 kW heating10 kW cooling3,703 kWh/yr3.5$1,222
Fujitsu AOTG36LBLA512 kW heating10 kW cooling4,079 kWh/yr3.5$1,346
Fujitsu AOTH36KBTA512 kW heating10 kW cooling4,088 kWh/yr4$1,349
Daikin 5MXM100RVMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431
TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440

Heat pumps similar to the TCL TFM4-36CHD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire H4M105S2AE12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
Hyundai HYSMHS10OTD12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
Hyundai HYSMHS10OT*12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
Carrier 38QUM105D8S511 kW heating10.7 kW cooling4,608 kWh/yr3$1,521
TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440
Midea MULMI0511B11 kW heating10.5 kW cooling4,536 kWh/yr3$1,497
Hisense AMW4-100U4RQA/AST-09UW4RMETD0111.1 kW heating10.5 kW cooling4,380 kWh/yr3$1,445
Hisense AMW4-100U4RQA11.1 kW heating10.5 kW cooling4,380 kWh/yr3$1,445

Compare TFM4-36CHD/DVO with another model

TCL TFM4-36CHD specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
10.70 kW
Cooling power input
2.75 kW
Rated heating capacity (7 Β°C)
12.30 kW
Heating power input
3.20 kW
EER, full load (tested)
3.80
COP, full load (tested)
3.82
Rated AEER
3.84
Rated ACOP
3.80
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56.9 dB(A)
Outdoor sound power
73.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL TFM4-36CHD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1371,385
Coldresidential3.02.05904,345
Mixedcommercial––1,506723
Mixedresidential3.02.59171,621
Hotcommercial––3,431159
Hotresidential3.53.02,652246
Part-load test points (18 values)
h__h2_ext_cap_power_rated
4100 W
c__t1_half_cap_power_rated
1140 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1200 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
11500 W
h__h1_half_cap_heat_cap_rated
6100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
900 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
5400 W

New Zealand E3 registration details

Registration number
AAC9761
GEMS registration id
175827
Status
approved, available (self-reported)
Registration expires
19 January 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.