c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
4,935 kWh
590 cooling + 4,345 heating
Estimated running cost
$1,629 / year
$136 / month Β· $16,286 over 10 years
Capacity
10.7 kW cooling
12.3 kW heating

9% more electricity than the median of 26 comparable 10 kW reverse cycle fixed registrations (4,539 kWh a year) in the cold zone. Uses less than 15% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hyundai HYSMHS10OTD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,935$1,629$16,286
Mixed zone 2,538$838$8,375
Hot zone 2,898$956$9,563

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MXZ-5F100VGD10 kW heating10 kW cooling3,703 kWh/yr3.5$1,222
Fujitsu AOTG36LBLA512 kW heating10 kW cooling4,079 kWh/yr3.5$1,346
Fujitsu AOTH36KBTA512 kW heating10 kW cooling4,088 kWh/yr4$1,349
Daikin 5MXM100RVMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431
TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440

Heat pumps similar to the Hyundai HYSMHS10OTD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire H4M105S2AE12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
Carrier 38QUM105D8S511 kW heating10.7 kW cooling4,608 kWh/yr3$1,521
TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440
TCL FMA-36I4HD/DVO10.5 kW heating10.5 kW cooling5,478 kWh/yr2.5$1,808
Midea MULMI0511B/MFAG20N11 kW heating10.5 kW cooling4,722 kWh/yr3$1,558
Hisense AMW4-100U4RQA/AST-09UW4RMETD0111.1 kW heating10.5 kW cooling4,380 kWh/yr3$1,445
Hisense AMW4-100U4RQA11.1 kW heating10.5 kW cooling4,380 kWh/yr3$1,445
Midea MULMI0511B11 kW heating10.5 kW cooling4,536 kWh/yr3$1,497

Compare HYSMHS10OTD with another model

Hyundai HYSMHS10OTD specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.70 kW
Cooling power input
2.75 kW
Rated heating capacity (7 Β°C)
12.30 kW
Heating power input
3.20 kW
EER, full load (tested)
3.80
COP, full load (tested)
3.82
Rated AEER
3.84
Rated ACOP
3.80
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
73.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hyundai HYSMHS10OTD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1371,385
Coldresidential3.02.05904,345
Mixedcommercial––1,506723
Mixedresidential3.02.59171,621
Hotcommercial––3,431159
Hotresidential3.53.02,652246
Part-load test points (18 values)
h__h2_ext_cap_power_rated
4100 W
c__t1_half_cap_power_rated
1140 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1200 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
11500 W
h__h1_half_cap_heat_cap_rated
6100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
900 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
5400 W

Other model numbers on registration AAC10193

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC10193
GEMS registration id
179984
Status
approved, available (self-reported)
Registration expires
1 June 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
HYSMHS10OT*
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.