c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
3,556 kWh
426 cooling + 3,130 heating
Estimated running cost
$1,173 / year
$98 / month Β· $11,735 over 10 years
Capacity
9 kW cooling
9.4 kW heating

23% less electricity than the median of 43 comparable 10 kW reverse cycle registrations (4,608 kWh a year) in the cold zone. Uses less than 95% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 53% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KM9.0 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,556$1,173$11,735
Mixed zone 1,820$601$6,006
Hot zone 2,050$677$6,765

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MXZ-4F80VGD8.8 kW heating8 kW cooling2,992 kWh/yr4$987
Carrier 38QUM080D8S48.3 kW heating8.1 kW cooling3,070 kWh/yr4$1,013
Bonaire H4M080S1AE8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021
Midea MULMI0480B8.5 kW heating8 kW cooling3,109 kWh/yr4$1,026
Toshiba RAS-4M27B2AVG-A9 kW heating8 kW cooling3,191 kWh/yr4$1,053

Heat pumps similar to the Kaden KM9.0

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QUM080D8S4-19.5 kW heating9 kW cooling3,592 kWh/yr4$1,185
LG ARUN030GSS010 kW heating9 kW cooling7,780 kWh/yr2$2,567
Daikin RXYMQ3AV10 kW heating9 kW cooling3,840 kWh/yr1.5$1,267
Daikin RXYMQ3A2V4A10 kW heating9 kW cooling3,815 kWh/yr1.5$1,259
Midea MDV-V100WHN8(At)9 kW heating9 kW cooling4,028 kWh/yr2$1,329
Samsung Electronics AM030RXMDEH/EU10.2 kW heating9.1 kW cooling4,735 kWh/yr2$1,563
Midea MULMI0490B9.6 kW heating9.2 kW cooling3,648 kWh/yr4$1,204
Actron Air MRC-090DS-49.6 kW heating9.2 kW cooling3,648 kWh/yr4$1,204

Compare KM9.0 with another model

Kaden KM9.0 specifications

Type
Reverse cycle
Configuration
–
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
9.40 kW
Heating power input
–
EER, full load (tested)
3.99
COP, full load (tested)
4.53
Rated AEER
3.70
Rated ACOP
4.03
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
68.6 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KM9.0 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––590985
Coldresidential4.02.04263,130
Mixedcommercial––863513
Mixedresidential3.53.06661,154
Hotcommercial––2,213124
Hotresidential4.53.51,863187
Part-load test points (21 values)
c__t1_min_cap_power_rated
551 W
h__h1_min_cap_power_rated
465 W
c__t1_half_cap_power_rated
910 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
880 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
2480 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2500 W
h__h1_half_cap_heat_cap_rated
4800 W
h__h2_full_cap_heat_cap_rated
8200 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
383 W
c__t1_min_cap_cooling_cap_rated
2200 W
c__low_temp_half_cap_power_rated
683 W
c__t1_half_cap_cooling_cap_rated
4320 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3320 W
c__low_temp_half_cap_cooling_cap_rated
4950 W

New Zealand E3 registration details

Registration number
AAC9912
GEMS registration id
–
Status
approved
Registration expires
1 March 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.