Samsung Electronics AM030RXMDEH/EU is a 9.1 kW reverse cycle multi-split / vrf heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8531).
- Energy rating (cooling)
- 2
- Heating: 1.5
- Annual electricity use
- 4,735 kWh
- 626 cooling + 4,109 heating
- Estimated running cost
- $1,563 / year
- $130 / month Β· $15,626 over 10 years
- Capacity
- 9.1 kW cooling
- 10.2 kW heating
3% less electricity than the median of 17 comparable 10 kW reverse cycle multi-split / vrf registrations (4,896 kWh a year) in the cold zone. Uses less than 53% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 41% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Samsung Electronics AM030RXMDEH running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,735 | $1,563 | $15,626 |
| Mixed zone | 2,497 | $824 | $8,240 |
| Hot zone | 2,849 | $940 | $9,402 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 9.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38VS00318SHCSS9 kW heating8 kW cooling3,321 kWh/yr | 3 | $1,096 | |
| Toshiba MCY-MHP0305HT9 kW heating8 kW cooling3,321 kWh/yr | 3 | $1,096 | |
| Mitsubishi Heavy Industries SCM80ZS-W9.3 kW heating8 kW cooling3,386 kWh/yr | 3.5 | $1,117 | |
| Kinghome KWHD(28)NK6PO8.8 kW heating8.2 kW cooling3,440 kWh/yr | 3.5 | $1,135 | |
| LG 4MXM80MA09.2 kW heating8.2 kW cooling3,713 kWh/yr | 3.5 | $1,225 |
Heat pumps similar to the Samsung Electronics AM030RXMDEH
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MDV-V100WHN8(At)9 kW heating9 kW cooling4,028 kWh/yr | 2 | $1,329 | |
| LG ARUN030GSS010 kW heating9 kW cooling7,780 kWh/yr | 2 | $2,567 | |
| Daikin RXYMQ3AV10 kW heating9 kW cooling3,840 kWh/yr | 1.5 | $1,267 | |
| Daikin RXYMQ3A2V4A10 kW heating9 kW cooling3,815 kWh/yr | 1.5 | $1,259 | |
| LG UHXM90MA110.1 kW heating8.8 kW cooling4,811 kWh/yr | 3 | $1,588 | |
| Hisense AVW-34HJFAH111.2 kW heating10 kW cooling5,245 kWh/yr | 3.5 | $1,731 | |
| Actron Air MMV-100CS12 kW heating10 kW cooling5,284 kWh/yr | 2 | $1,744 | |
| Mdv MV8M-100WV2N812 kW heating10 kW cooling5,284 kWh/yr | 2 | $1,744 |
Compare AM030RXMDEH/EU with another model
Samsung Electronics AM030RXMDEH specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 9.05 kW
- Cooling power input
- 2.26 kW
- Rated heating capacity (7 Β°C)
- 10.15 kW
- Heating power input
- 2.17 kW
- EER, full load (tested)
- 4.00
- COP, full load (tested)
- 4.68
- Rated AEER
- 3.86
- Rated ACOP
- 4.50
- Standby power (PIA)
- 25.7 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 68 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China, South Korea
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Samsung Electronics AM030RXMDEH zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,421 | 1,366 |
| Coldresidential | residential | 2.0 | 1.5 | 626 | 4,109 |
| Mixedcommercial | commercial | β | β | 1,755 | 704 |
| Mixedresidential | residential | 2.0 | 2.0 | 955 | 1,542 |
| Hotcommercial | commercial | β | β | 3,499 | 180 |
| Hotresidential | residential | 2.5 | 2.5 | 2,584 | 265 |
Part-load test points (24 values)
- h__h1_min_cap_power_rated
- 990 W
- h__h2_ext_cap_power_rated
- 1680 W
- c__t1_half_cap_power_rated
- 1000 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1140 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 4380 W
- h__h2_ext_cap_heat_cap_rated
- 7000 W
- h__h1_half_cap_heat_cap_rated
- 5340 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 1040 W
- c__low_temp_full_cap_power_rated
- 2065.64 W
- c__low_temp_half_cap_power_rated
- 914 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 4850 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 4300 W
- c__low_temp_full_cap_cooling_cap_rated
- 9746.85 W
- c__low_temp_half_cap_cooling_cap_rated
- 5223.45 W
New Zealand E3 registration details
- Registration number
- AAC8531
- GEMS registration id
- 165333
- Status
- approved, available (self-reported)
- Registration expires
- 24 November 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 19
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.