c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
3,795 kWh
457 cooling + 3,338 heating
Estimated running cost
$1,252 / year
$104 / month Β· $12,524 over 10 years
Capacity
8 kW cooling
8.1 kW heating

5% more electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 31% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KS28 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,795$1,252$12,524
Mixed zone 1,926$636$6,356
Hot zone 2,338$772$7,715

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr3$875
Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr3$879
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr4$906
Daikin RXM71AVMA / FTXM71AVMA8 kW heating7.1 kW cooling2,764 kWh/yr3.5$912

Heat pumps similar to the Kaden KS28

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QRG080N8/42QRG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Solar Acdc DGWA1-ACDCBLW-30KR29 kW heating8 kW cooling3,418 kWh/yr4$1,128
Kogan KASSSAC80H*8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Panasonic CU-Z80DKR / CS-Z80DKR9 kW heating8 kW cooling3,422 kWh/yr3.5$1,129
Carrier 38QAG080N8/42QAG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Panasonic CU-*Z80DKR / CU-*Z80DKR9 kW heating8 kW cooling3,422 kWh/yr3.5$1,129
Haier 1U80QAFFRA / AS80QFFHRA9 kW heating8 kW cooling3,455 kWh/yr3.5$1,140
Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083

Compare KS28 with another model

Kaden KS28 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
8.00 kW
Cooling power input
2.40 kW
Rated heating capacity (7 Β°C)
8.10 kW
Heating power input
2.40 kW
EER, full load (tested)
3.27
COP, full load (tested)
3.30
Rated AEER
3.33
Rated ACOP
3.37
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
65 dB(A)
Outdoor sound power
70 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KS28 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––7351,014
Coldresidential3.01.54573,338
Mixedcommercial––1,056512
Mixedresidential3.02.07151,211
Hotcommercial––2,798100
Hotresidential3.02.52,177161
Part-load test points (25 values)
c__t1_min_cap_power_rated
760 W
h__h1_min_cap_power_rated
500 W
h__h2_ext_cap_power_rated
2975 W
c__t1_half_cap_power_rated
910 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
980 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2280 W
h__h2_ext_cap_heat_cap_rated
7020 W
h__h1_half_cap_heat_cap_rated
4050 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
510 W
c__t1_min_cap_cooling_cap_rated
3125 W
c__low_temp_full_cap_power_rated
2193.6 W
c__low_temp_half_cap_power_rated
831.74 W
c__t1_half_cap_cooling_cap_rated
4000 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
3070 W
c__low_temp_full_cap_cooling_cap_rated
8616 W
c__low_temp_half_cap_cooling_cap_rated
4308 W

New Zealand E3 registration details

Registration number
AAC6822
GEMS registration id
148148
Status
approved, available (self-reported)
Registration expires
17 July 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com/global. How the derived figures are calculated.