c/kWh
Energy rating (cooling)
1.5
Heating: 0.5
Annual electricity use
1,642 kWh
226 cooling + 1,416 heating
Estimated running cost
$542 / year
$45 / month Β· $5,419 over 10 years
Capacity
2.8 kW cooling
2.5 kW heating

6% more electricity than the median of 21 comparable 2.5 kW reverse cycle window / wall registrations (1,546 kWh a year) in the cold zone. Uses less than 10% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 79% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kelvinator WH27 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,642$542$5,419
Mixed zone 889$293$2,934
Hot zone 1,096$362$3,617

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Kogan KAWDACR27T*2.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472

Heat pumps similar to the Kelvinator WH27

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Westinghouse WWH28HWC2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510
TECO TWW27HFWDG2.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542
Midea MWFF26H2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510
Kaden KW092.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542
Gree GJH09AK-K6NRNG2A2.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542
TECO TWW28HVAG2.4 kW heating2.8 kW cooling1,735 kWh/yr2$573
Gree GJH09AK-K6NRNB3C2.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542
Midea MWFF28H2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510

Compare WH27 with another model

Kelvinator WH27 specifications

Type
Reverse cycle
Configuration
Window / wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.80 kW
Cooling power input
0.84 kW
Rated heating capacity (7 Β°C)
2.45 kW
Heating power input
0.74 kW
EER, full load (tested)
3.36
COP, full load (tested)
3.47
Rated AEER
3.32
Rated ACOP
3.30
Standby power (PIA)
0.8 W
Compressor
Fixed speed
Refrigerant
R32
Power supply
Single phase
Indoor sound power
59.7 dB(A)
Outdoor sound power
65.6 dB(A)
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
560 Γ— 375 Γ— 668 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kelvinator WH27 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––514446
Coldresidential1.50.52261,416
Mixedcommercial––640235
Mixedresidential1.50.5344545
Hotcommercial––1,39447
Hotresidential2.01.01,01977
Part-load test points (6 values)
h__h2_full_cap_power_rated
620 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
1500 W
c__low_temp_full_cap_power_rated
755 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
3040 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
WH27AAC84322215

Other model numbers on registration AAC8422

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC8422
GEMS registration id
164204
Status
approved, available (self-reported)
Registration expires
28 August 2029
Registered for sale in
Australia, New Zealand
Family
WH27
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 5

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.