Kogan KASSSAC80HF is a 8 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10439).
- Energy rating (cooling)
- 4.5
- Heating: 2
- Annual electricity use
- 3,283 kWh
- 363 cooling + 2,920 heating
- Estimated running cost
- $1,083 / year
- $90 / month Β· $10,834 over 10 years
- Capacity
- 8 kW cooling
- 8.2 kW heating
9% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 99% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 57% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kogan KASSSAC80HF running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,283 | $1,083 | $10,834 |
| Mixed zone | 1,662 | $548 | $5,485 |
| Hot zone | 1,834 | $605 | $6,052 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr | 3 | $875 | |
| Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr | 3 | $879 | |
| Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr | 0.5 | $883 | |
| Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr | 4 | $906 | |
| Daikin RXM71AVMA / FTXM71AVMA8 kW heating7.1 kW cooling2,764 kWh/yr | 3.5 | $912 |
Heat pumps similar to the Kogan KASSSAC80HF
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Haier 1U80QAFFRA / AS80QFFHRA9 kW heating8 kW cooling3,455 kWh/yr | 3.5 | $1,140 | |
| Hisense HAWJ28KR8 kW heating8 kW cooling3,466 kWh/yr | 3 | $1,144 | |
| Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr | 3.5 | $1,112 | |
| Hisense HAWG28KR8 kW heating8 kW cooling3,466 kWh/yr | 3 | $1,144 | |
| Panasonic CU-HZ80DKR / CS-HZ80DKR9 kW heating8 kW cooling3,422 kWh/yr | 3.5 | $1,129 | |
| Carrier 38QRG080N8/42QRG080N88.2 kW heating8 kW cooling3,371 kWh/yr | 3.5 | $1,112 | |
| Panasonic CU-*Z80DKR / CU-*Z80DKR9 kW heating8 kW cooling3,422 kWh/yr | 3.5 | $1,129 | |
| Solar Acdc DGWA1-ACDCBLW-30KR29 kW heating8 kW cooling3,418 kWh/yr | 4 | $1,128 |
Compare KASSSAC80HF with another model
Kogan KASSSAC80HF specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 8.00 kW
- Cooling power input
- 2.34 kW
- Rated heating capacity (7 Β°C)
- 8.20 kW
- Heating power input
- 2.33 kW
- EER, full load (tested)
- 3.45
- COP, full load (tested)
- 3.65
- Rated AEER
- 3.40
- Rated ACOP
- 3.50
- Standby power (PIA)
- 3.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 65.3 dB(A)
- Outdoor sound power
- 67.2 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kogan KASSSAC80HF zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 331 | 907 |
| Coldresidential | residential | 4.5 | 2.0 | 363 | 2,920 |
| Mixedcommercial | commercial | β | β | 694 | 465 |
| Mixedresidential | residential | 4.0 | 2.5 | 593 | 1,069 |
| Hotcommercial | commercial | β | β | 1,756 | 95 |
| Hotresidential | residential | 4.5 | 3.0 | 1,684 | 150 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 3320 W
- c__t1_half_cap_power_rated
- 900 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 770 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 8200 W
- h__h1_half_cap_heat_cap_rated
- 4100 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 540 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3950 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 3850 W
Other model numbers on registration AAC10439
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC10439
- GEMS registration id
- 182257
- Status
- approved, available (self-reported)
- Registration expires
- 9 September 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- KASSSAC80H*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 22 September 2026; last checked 23 September 2026. How the derived figures are calculated.