New Zealand Β· costs in NZD

Cooling only split system air conditioner
Lennox TSA060S41-1/CH33-50/60C-2F-3 Heat Pump
Lennox TSA060S41-1/CH33-50/60C-2F-3 is a 14.8 kW cooling only ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC6319).
- Energy rating (cooling)
- 1.5
- Annual electricity use
- 1,182 kWh
- Estimated running cost
- $390 / year
- $33 / month Β· $3,901 over 10 years
- Capacity
- 14.8 kW cooling
Only 4 comparable registrations in this cohort, so no percentile is shown.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 86% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Lennox TSA060S41-1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,182 | $390 | $3,901 |
| Mixed zone | 1,756 | $579 | $5,795 |
| Hot zone | 4,947 | $1,633 | $16,325 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 14.8 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Bonaire CRC6940014/CRC694011414 kW cooling733 kWh/yr | 3.5 | $242 | |
| Brivis DONSC17Z71 / DINXU17Z716.2 kW cooling897 kWh/yr | 3 | $296 | |
| Lennox TSA048S41-3/CH33-44/48B-2F-313.4 kW cooling1,132 kWh/yr | 1.5 | $374 | |
| Lennox TSA048S4N42M/CH33-44/48B-2F-313.4 kW cooling1,132 kWh/yr | 1.5 | $374 |
Heat pumps similar to the Lennox TSA060S41-1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air CCA150S / EAA150S14.8 kW cooling1,148 kWh/yr | 2 | $379 | |
| Bonaire CRC6940014/CRC694011414 kW cooling733 kWh/yr | 3.5 | $242 | |
| Braemar KCHV160D1B/KACV160D1S16 kW cooling1,290 kWh/yr | 1.5 | $426 | |
| Brivis DONSC17Z71 / DINXU17Z716.2 kW cooling897 kWh/yr | 3 | $296 | |
| Actron Air CCA170S / EAA170S16.5 kW cooling1,300 kWh/yr | 2 | $429 |
Other Lennox models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Lennox TSA048S4N42M/CH33-44/48B-2F-313.4 kW cooling1,132 kWh/yr | 1.5 | $374 | |
| Lennox TSA048S41-313.4 kW cooling1,132 kWh/yr | 1.5 | $374 |
Compare TSA060S41-1/CH33-50/60C-2F-3 with another model
Lennox TSA060S41-1 specifications
- Type
- Cooling only
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 14.78 kW
- Cooling power input
- 3.89 kW
- Rated heating capacity (7 Β°C)
- β
- Heating power input
- β
- EER, full load (tested)
- 3.68
- COP, full load (tested)
- β
- Rated AEER
- 3.68
- Rated ACOP
- β
- Standby power (PIA)
- 37.6 W
- Compressor
- Fixed speed
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 80 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- United States of America
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Lennox TSA060S41-1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 2,591 | β |
| Coldresidential | residential | 1.5 | β | 1,182 | β |
| Mixedcommercial | commercial | β | β | 3,173 | β |
| Mixedresidential | residential | 1.5 | β | 1,756 | β |
| Hotcommercial | commercial | β | β | 6,746 | β |
| Hotresidential | residential | 2.0 | β | 4,947 | β |
Part-load test points (1 values)
- c__low_temp_have_full_cap_results
- No
Other model numbers on registration AAC6319
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC6319
- GEMS registration id
- 142187
- Status
- approved, available (self-reported)
- Registration expires
- 27 October 2026
- Registered for sale in
- Australia, New Zealand
- Family
- TSA060S41-1
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: lennox.com. How the derived figures are calculated.