New Zealand Β· costs in NZD

Reverse cycle air conditioner
LG ARUN040GSS0 Heat Pump
LG ARUN040GSS0 is a 12.1 kW reverse cycle heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8751).
- Energy rating (cooling)
- 2
- Heating: 0
- Annual electricity use
- 10,145 kWh
- 847 cooling + 9,298 heating
- Estimated running cost
- $3,348 / year
- $279 / month Β· $33,479 over 10 years
- Capacity
- 12.1 kW cooling
- 12.5 kW heating
83% more electricity than the median of 35 comparable 12.5 kW reverse cycle registrations (5,553 kWh a year) in the cold zone. Uses less than 0% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 13% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
LG ARUN040GSS0 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 10,145 | $3,348 | $33,479 |
| Mixed zone | 4,910 | $1,620 | $16,203 |
| Hot zone | 4,013 | $1,324 | $13,243 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 12.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38QUM110D8S512.5 kW heating11.6 kW cooling4,367 kWh/yr | 3.5 | $1,441 | |
| Daikin RSUYQ4AVMA12.5 kW heating11.2 kW cooling4,422 kWh/yr | 2.5 | $1,459 | |
| Daikin RSUYQ4A2VMA12.5 kW heating11.2 kW cooling4,424 kWh/yr | 2.5 | $1,460 | |
| Carrier 38VS004181HCSG12.5 kW heating12.1 kW cooling4,445 kWh/yr | 3.5 | $1,467 | |
| Toshiba MCY-MHP0404HS-A12.5 kW heating12.1 kW cooling4,445 kWh/yr | 3.5 | $1,467 |
Heat pumps similar to the LG ARUN040GSS0
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AJT040LCLBH12.1 kW heating12.1 kW cooling4,864 kWh/yr | 2.5 | $1,605 | |
| Hisense AVW-41HJFHH214 kW heating12.1 kW cooling5,553 kWh/yr | 3.5 | $1,832 | |
| Fujitsu AJT040LCLCH12.1 kW heating12.1 kW cooling4,864 kWh/yr | 2.5 | $1,605 | |
| Toshiba MCY-MHP0404HS-A12.5 kW heating12.1 kW cooling4,445 kWh/yr | 3.5 | $1,467 | |
| Carrier 38VS004181HCSG12.5 kW heating12.1 kW cooling4,445 kWh/yr | 3.5 | $1,467 | |
| Hisense AWV-41HJFHH214 kW heating12.1 kW cooling5,553 kWh/yr | 3.5 | $1,832 | |
| Bonaire H5M125S1AE12.2 kW heating12.2 kW cooling4,758 kWh/yr | 3.5 | $1,570 | |
| Kaden KM4612 kW heating12 kW cooling5,342 kWh/yr | 3.5 | $1,763 |
Compare ARUN040GSS0 with another model
LG ARUN040GSS0 specifications
- Type
- Reverse cycle
- Configuration
- β
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 12.10 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 12.50 kW
- Heating power input
- β
- EER, full load (tested)
- 4.08
- COP, full load (tested)
- 4.40
- Rated AEER
- 3.86
- Rated ACOP
- 4.04
- Standby power (PIA)
- 25.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 72 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- South Korea
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
LG ARUN040GSS0 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,863 | 2,496 |
| Coldresidential | residential | 2.0 | 0.0 | 847 | 9,298 |
| Mixedcommercial | commercial | β | β | 2,294 | 1,290 |
| Mixedresidential | residential | 2.0 | 0.0 | 1,274 | 3,636 |
| Hotcommercial | commercial | β | β | 4,883 | 251 |
| Hotresidential | residential | 2.5 | 1.0 | 3,600 | 413 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 1202 W
- c__t1_half_cap_power_rated
- 1526 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1506 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 4690 W
- h__h1_half_cap_heat_cap_rated
- 6250 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 6050 W
- c__low_temp_have_half_cap_results
- No
New Zealand E3 registration details
- Registration number
- AAC8751
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 31 March 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- 20