c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
4,493 kWh
580 cooling + 3,913 heating
Estimated running cost
$1,483 / year
$124 / month Β· $14,827 over 10 years
Capacity
9.5 kW cooling
10.8 kW heating

6% less electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 71% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 43% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG UU100WR3 U30 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,493$1,483$14,827
Mixed zone 2,350$776$7,755
Hot zone 2,784$919$9,187

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Carrier 38QSM090D8S/42QSM090D8S9.3 kW heating8.7 kW cooling3,653 kWh/yr3.5$1,205
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr4$1,208
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr3.5$1,217

Heat pumps similar to the LG UU100WR3 U30

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr4.5$1,395
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr3.5$1,217
Carrier 38QSP090N8/42QSP090N810.5 kW heating9 kW cooling3,834 kWh/yr3.5$1,265
Daikin RZAV100CV1 / FBA100BVMA11.2 kW heating10 kW cooling4,295 kWh/yr3$1,417
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr4$1,208

Other LG models of similar capacity

ModelStarsEst. cost / yrCompare
LG UU100WR2 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling5,594 kWh/yr2$1,846

Compare UU100WR3 U30/UMN100M2 N20 with another model

LG UU100WR3 U30 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.50 kW
Cooling power input
2.50 kW
Rated heating capacity (7 Β°C)
10.80 kW
Heating power input
2.77 kW
EER, full load (tested)
3.94
COP, full load (tested)
4.22
Rated AEER
3.72
Rated ACOP
3.83
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China, South Korea

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG UU100WR3 U30 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,2501,256
Coldresidential2.52.05803,913
Mixedcommercial––1,561658
Mixedresidential2.52.58931,457
Hotcommercial––3,418154
Hotresidential3.03.02,549235
Part-load test points (20 values)
h__h2_ext_cap_power_rated
2930 W
c__t1_half_cap_power_rated
1000 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1090 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
9070 W
h__h1_half_cap_heat_cap_rated
5450 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
2285 W
c__low_temp_half_cap_power_rated
914 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4800 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
10231.5 W
c__low_temp_half_cap_cooling_cap_rated
5169.599999999999 W

New Zealand E3 registration details

Registration number
AAC8095
GEMS registration id
160017
Status
approved, available (self-reported)
Registration expires
13 March 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.