c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
1,162 kWh
125 cooling + 1,037 heating
Estimated running cost
$383 / year
$32 / month Β· $3,835 over 10 years
Capacity
2.6 kW cooling
3.2 kW heating

8% more electricity than the median of 178 comparable 2.5 kW reverse cycle split system registrations (1,074 kWh a year) in the cold zone. Uses less than 27% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 86% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG WS09TWU running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,162$383$3,835
Mixed zone 584$193$1,927
Hot zone 622$205$2,053

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265

Heat pumps similar to the LG WS09TWU

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HONRPX25/HINRPX25M3.3 kW heating2.6 kW cooling1,009 kWh/yr6.5$333
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Kaden KSI092.7 kW heating2.6 kW cooling923 kWh/yr5$305
Midea MFCA26VA-W/MFCA26VA-N2.6 kW heating2.6 kW cooling815 kWh/yr6.5$269
Kaden KS092.8 kW heating2.6 kW cooling1,018 kWh/yr4.5$336
TCL TAC-10CHSD/XA72IG3.3 kW heating2.6 kW cooling1,122 kWh/yr5$370
Kogan KASSSAC26TB3.3 kW heating2.6 kW cooling1,122 kWh/yr5$370
Kogan KASSSAC26T*3.3 kW heating2.6 kW cooling1,122 kWh/yr5$370

Compare WS09TWU / WS09TWN with another model

LG WS09TWU specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.60 kW
Cooling power input
0.60 kW
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
0.74 kW
EER, full load (tested)
4.68
COP, full load (tested)
4.72
Rated AEER
4.28
Rated ACOP
4.27
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
60.2 dB(A)
Outdoor sound power
55.9 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
837 Γ— 308 Γ— 189 mm
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG WS09TWU zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––195335
Coldresidential4.02.51251,037
Mixedcommercial––282176
Mixedresidential4.03.0193391
Hotcommercial––69938
Hotresidential4.53.056260
Part-load test points (23 values)
c__t1_min_cap_power_rated
220 W
h__h2_ext_cap_power_rated
1280 W
c__t1_half_cap_power_rated
280 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
300 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3420 W
h__h1_half_cap_heat_cap_rated
1600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
151 W
c__t1_min_cap_cooling_cap_rated
950 W
c__low_temp_full_cap_power_rated
548.4 W
c__low_temp_half_cap_power_rated
218 W
c__t1_half_cap_cooling_cap_rated
1300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1000 W
c__low_temp_full_cap_cooling_cap_rated
2800.2 W
c__low_temp_half_cap_cooling_cap_rated
1400 W

New Zealand E3 registration details

Registration number
AAC8308
GEMS registration id
162458
Status
approved, available (self-reported)
Registration expires
23 June 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.