c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
4,988 kWh
642 cooling + 4,346 heating
Estimated running cost
$1,646 / year
$137 / month Β· $16,460 over 10 years
Capacity
12.5 kW cooling
13.5 kW heating

19% less electricity than the median of 146 comparable 12.5 kW reverse cycle ducted split system registrations (6,125 kWh a year) in the cold zone. Uses less than 90% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mdv running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,988$1,646$16,460
Mixed zone 2,685$886$8,861
Hot zone 3,208$1,059$10,586

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Panasonic U-125PZ4R5 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr3.5$1,583

Heat pumps similar to the Mdv

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr4$1,594
Kaden KDI4213 kW heating12.5 kW cooling4,853 kWh/yr3.5$1,601
Panasonic U-125PZ4R8 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Kaden KDI42 / KDI4213 kW heating12.5 kW cooling4,853 kWh/yr3.5$1,601
TECO TDS-TSO125HVFM13.5 kW heating12.5 kW cooling5,135 kWh/yr4$1,695
Panasonic U-125PZ4R8 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,848 kWh/yr3.5$1,600

Compare C-UV-125N8-QC3W / CDV-125A6N8-QC3W with another model

Mdv specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.60 kW
Rated heating capacity (7 Β°C)
13.50 kW
Heating power input
3.20 kW
EER, full load (tested)
3.49
COP, full load (tested)
4.12
Rated AEER
3.43
Rated ACOP
4.16
Standby power (PIA)
13.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
69.7 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mdv zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9601,385
Coldresidential3.52.56424,346
Mixedcommercial––1,274742
Mixedresidential3.52.59941,691
Hotcommercial––3,507168
Hotresidential3.53.02,947261
Part-load test points (25 values)
c__t1_min_cap_power_rated
1020 W
h__h1_min_cap_power_rated
580 W
h__h2_ext_cap_power_rated
5740 W
c__t1_half_cap_power_rated
1260 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1250 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2960 W
h__h2_ext_cap_heat_cap_rated
16120 W
h__h1_half_cap_heat_cap_rated
6200 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
530 W
c__t1_min_cap_cooling_cap_rated
3750 W
c__low_temp_full_cap_power_rated
3290.4 W
c__low_temp_half_cap_power_rated
1100 W
c__t1_half_cap_cooling_cap_rated
5950 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3450 W
c__low_temp_full_cap_cooling_cap_rated
13462.5 W
c__low_temp_half_cap_cooling_cap_rated
6500 W

New Zealand E3 registration details

Registration number
AAC7213
GEMS registration id
151597
Status
approved, available (self-reported)
Registration expires
20 December 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.