New Zealand Β· costs in NZD

Reverse cycle multi-split / vrf air conditioner
Midea MDV-V244WN1(AU)-R Heat Pump
Midea MDV-V244WN1(AU)-R is a 20 kW reverse cycle multi-split / vrf heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9653).
- Energy rating (cooling)
- 5
- Heating: 2.5
- Annual electricity use
- 8,242 kWh
- 792 cooling + 7,450 heating
- Estimated running cost
- $2,720 / year
- $227 / month Β· $27,199 over 10 years
- Capacity
- 20 kW cooling
- 24.4 kW heating
16% less electricity than the median of 36 comparable 20 kW reverse cycle multi-split / vrf registrations (9,798 kWh a year) in the cold zone. Uses less than 75% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 18% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Midea MDV-V244WN1(AU)-R running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 8,242 | $2,720 | $27,199 |
| Mixed zone | 3,935 | $1,299 | $12,986 |
| Hot zone | 3,856 | $1,272 | $12,725 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 20 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Smart User SMV-V200W/N120 kW heating18 kW cooling6,654 kWh/yr | 3.5 | $2,196 | |
| Silicon Electronics EMV-V200W/N120 kW heating18 kW cooling6,654 kWh/yr | 3.5 | $2,196 | |
| Smart User SMV-V200W/N120 kW heating18 kW cooling6,661 kWh/yr | 3 | $2,198 | |
| Aux ARV-H180/NR1B-AU21.5 kW heating18.1 kW cooling7,058 kWh/yr | 3.5 | $2,329 | |
| Silicon Electronics EMV-V230W/N123 kW heating21 kW cooling7,528 kWh/yr | 4 | $2,484 |
Heat pumps similar to the Midea MDV-V244WN1(AU)-R
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai MVRFON6H2023.5 kW heating20 kW cooling7,963 kWh/yr | 3.5 | $2,628 | |
| Aux ARV-H200/NR1B-AU24.1 kW heating20 kW cooling7,585 kWh/yr | 3.5 | $2,503 | |
| Daikin RSUYQ7AYM22.4 kW heating20 kW cooling8,291 kWh/yr | 2.5 | $2,736 | |
| Mdv MVI-200WV2GN1(A)22 kW heating20 kW cooling11,751 kWh/yr | 2 | $3,878 | |
| Airion AR-VI200WV2R22 kW heating20 kW cooling11,751 kWh/yr | 2 | $3,878 | |
| Hisense AVW-68HJFAH122.4 kW heating20 kW cooling9,364 kWh/yr | 3.5 | $3,090 |
Other Midea models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MDV-V235WN1(AU)-A23.5 kW heating20 kW cooling7,963 kWh/yr | 3.5 | $2,628 | |
| Midea MDV-V235WN1(AU)-R23.5 kW heating20 kW cooling7,963 kWh/yr | 3.5 | $2,628 |
Compare MDV-V244WN1(AU)-R with another model
Midea MDV-V244WN1(AU)-R specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 20.00 kW
- Cooling power input
- 4.13 kW
- Rated heating capacity (7 Β°C)
- 24.40 kW
- Heating power input
- 5.45 kW
- EER, full load (tested)
- 4.78
- COP, full load (tested)
- 4.50
- Rated AEER
- 4.73
- Rated ACOP
- 4.39
- Standby power (PIA)
- 30.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 78 dB(A)
- Demand response (AS/NZS 4755)
- β
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MDV-V244WN1(AU)-R zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,058 | 2,274 |
| Coldresidential | residential | 5.0 | 2.5 | 792 | 7,450 |
| Mixedcommercial | commercial | β | β | 1,608 | 1,156 |
| Mixedresidential | residential | 4.5 | 3.5 | 1,227 | 2,708 |
| Hotcommercial | commercial | β | β | 4,114 | 270 |
| Hotresidential | residential | 5.5 | 4.5 | 3,441 | 415 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 830 W
- h__h1_min_cap_power_rated
- 1030 W
- h__h2_ext_cap_power_rated
- 7200 W
- c__t1_half_cap_power_rated
- 1600 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 2150 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 6700 W
- h__h2_ext_cap_heat_cap_rated
- 22400 W
- h__h1_half_cap_heat_cap_rated
- 12400 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 545 W
- c__t1_min_cap_cooling_cap_rated
- 5400 W
- c__low_temp_half_cap_power_rated
- 1160 W
- c__t1_half_cap_cooling_cap_rated
- 10300 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 5500 W
- c__low_temp_half_cap_cooling_cap_rated
- 10300 W
New Zealand E3 registration details
- Registration number
- AAC9653
- GEMS registration id
- 175230
- Status
- approved, available (self-reported)
- Registration expires
- 10 December 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 20
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.