c/kWh
Energy rating (cooling)
3.5
Heating: 1.5
Annual electricity use
3,904 kWh
409 cooling + 3,495 heating
Estimated running cost
$1,288 / year
$107 / month Β· $12,883 over 10 years
Capacity
8 kW cooling
8.5 kW heating

8% more electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 25% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFAB-80WC running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,904$1,288$12,883
Mixed zone 1,828$603$6,032
Hot zone 2,095$691$6,914

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr3$875
Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr3$879
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr4$906
Daikin RXM71AVMA / FTXM71AVMA8 kW heating7.1 kW cooling2,764 kWh/yr3.5$912

Heat pumps similar to the Midea MFAB-80WC

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KASSSAC80HC8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Panasonic CU-*Z80DKR / CU-*Z80DKR9 kW heating8 kW cooling3,422 kWh/yr3.5$1,129
Haier 1U80QAFFRA / AS80QFFHRA9 kW heating8 kW cooling3,455 kWh/yr3.5$1,140
Kogan KASSSAC80HD8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Carrier 38QRG080N8/42QRG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Panasonic CU-RZ80DKR / CS-RZ80DKR9 kW heating8 kW cooling3,422 kWh/yr3.5$1,129
Solar Acdc DGWA1-ACDCBLW-30KR29 kW heating8 kW cooling3,418 kWh/yr4$1,128
Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112

Compare MFAB-80WC/MFAB-80NC with another model

Midea MFAB-80WC specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
8.00 kW
Cooling power input
2.35 kW
Rated heating capacity (7 Β°C)
8.50 kW
Heating power input
2.25 kW
EER, full load (tested)
3.42
COP, full load (tested)
3.70
Rated AEER
3.40
Rated ACOP
3.77
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64 dB(A)
Outdoor sound power
67 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFAB-80WC zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5721,046
Coldresidential3.51.54093,495
Mixedcommercial––918483
Mixedresidential3.52.06531,175
Hotcommercial––2,39891
Hotresidential3.53.51,950145
Part-load test points (25 values)
c__t1_min_cap_power_rated
780 W
h__h1_min_cap_power_rated
415 W
h__h2_ext_cap_power_rated
2860 W
c__t1_half_cap_power_rated
885 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
800 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2130 W
h__h2_ext_cap_heat_cap_rated
6320 W
h__h1_half_cap_heat_cap_rated
4100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
500 W
c__t1_min_cap_cooling_cap_rated
3790 W
c__low_temp_full_cap_power_rated
2147.9 W
c__low_temp_half_cap_power_rated
690 W
c__t1_half_cap_cooling_cap_rated
4100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3280 W
c__low_temp_full_cap_cooling_cap_rated
8616 W
c__low_temp_half_cap_cooling_cap_rated
4250 W

New Zealand E3 registration details

Registration number
AAC6278
GEMS registration id
142162
Status
approved, available (self-reported)
Registration expires
12 October 2026
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9