New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Midea MFAG60VB-W/MFAG60VB-N Heat Pump
Midea MFAG60VB-W/MFAG60VB-N is a 6 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8868).
- Energy rating (cooling)
- 4
- Heating: 1.5
- Annual electricity use
- 2,763 kWh
- 298 cooling + 2,465 heating
- Estimated running cost
- $912 / year
- $76 / month Β· $9,118 over 10 years
- Capacity
- 6 kW cooling
- 6.5 kW heating
1% more electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 39% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 65% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Midea MFAG60VB-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,763 | $912 | $9,118 |
| Mixed zone | 1,340 | $442 | $4,422 |
| Hot zone | 1,538 | $508 | $5,075 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TCL TAC-VX18HSV/U*5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| Hyundai HYSSSAC53TB5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| TCL TAC-VX18HSV/UB5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 |
Heat pumps similar to the Midea MFAG60VB-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM60AVMA / FTXM60AVMA7.2 kW heating6 kW cooling2,420 kWh/yr | 5 | $799 | |
| Toshiba RAS-22ZAVSG-A / RAS-22ZKVSG-A6.9 kW heating6 kW cooling2,602 kWh/yr | 4 | $859 | |
| Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling2,517 kWh/yr | 5 | $831 | |
| Mitsubishi Electric MUZ-AP60VGD2/MSZ-AP60VGKD26.8 kW heating6 kW cooling2,490 kWh/yr | 4.5 | $822 | |
| Hitachi RAC-VJ60PHAT/RAK-VJ60PHAT7 kW heating6 kW cooling2,619 kWh/yr | 4.5 | $864 | |
| Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGD26.8 kW heating6 kW cooling2,490 kWh/yr | 4.5 | $822 | |
| Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr | 5 | $798 | |
| Hitachi RAC-S60YHAB/RAS-S60YHAB7 kW heating6 kW cooling2,643 kWh/yr | 4 | $872 |
Compare MFAG60VB-W/MFAG60VB-N with another model
Midea MFAG60VB-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.00 kW
- Cooling power input
- 1.74 kW
- Rated heating capacity (7 Β°C)
- 6.50 kW
- Heating power input
- 1.70 kW
- EER, full load (tested)
- 3.39
- COP, full load (tested)
- 3.73
- Rated AEER
- 3.45
- Rated ACOP
- 3.81
- Standby power (PIA)
- 0.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 59.6 dB(A)
- Outdoor sound power
- 67.1 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MFAG60VB-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 419 | 768 |
| Coldresidential | residential | 4.0 | 1.5 | 298 | 2,465 |
| Mixedcommercial | commercial | β | β | 648 | 368 |
| Mixedresidential | residential | 3.5 | 2.5 | 475 | 865 |
| Hotcommercial | commercial | β | β | 1,741 | 71 |
| Hotresidential | residential | 4.0 | 3.0 | 1,425 | 113 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 500 W
- h__h1_min_cap_power_rated
- 459 W
- h__h2_ext_cap_power_rated
- 1738 W
- c__t1_half_cap_power_rated
- 650 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 601 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2380 W
- h__h2_ext_cap_heat_cap_rated
- 4960 W
- h__h1_half_cap_heat_cap_rated
- 3050 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 320 W
- c__t1_min_cap_cooling_cap_rated
- 2100 W
- c__low_temp_half_cap_power_rated
- 500 W
- c__t1_half_cap_cooling_cap_rated
- 3000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2170 W
- c__low_temp_half_cap_cooling_cap_rated
- 3100 W
New Zealand E3 registration details
- Registration number
- AAC8868
- GEMS registration id
- 169406
- Status
- approved, available (self-reported)
- Registration expires
- 21 May 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.