c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
3,874 kWh
426 cooling + 3,448 heating
Estimated running cost
$1,278 / year
$107 / month Β· $12,784 over 10 years
Capacity
9 kW cooling
9.5 kW heating

13% less electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 76% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFAG90VB-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,874$1,278$12,784
Mixed zone 1,882$621$6,211
Hot zone 2,201$726$7,263

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Kogan KASSSAC80HB8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Carrier 38QAG080N8/42QAG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112

Heat pumps similar to the Midea MFAG90VB-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Rinnai HONRTX90/HINRTX909.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Panasonic U-100PZ3R8/S-100PK3R9 kW heating9 kW cooling3,534 kWh/yr2.5$1,166
Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Rinnai HSNRTX909.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HC9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Panasonic U-100PZ3R5/S-100PK3R9 kW heating9 kW cooling3,534 kWh/yr2.5$1,166

Compare MFAG90VB-W/MFAG90VB-N with another model

Midea MFAG90VB-W specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.00 kW
Cooling power input
2.58 kW
Rated heating capacity (7 Β°C)
9.50 kW
Heating power input
2.47 kW
EER, full load (tested)
3.55
COP, full load (tested)
3.93
Rated AEER
3.48
Rated ACOP
3.84
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
65.2 dB(A)
Outdoor sound power
68.3 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFAG90VB-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––7351,030
Coldresidential4.02.04263,448
Mixedcommercial––1,030508
Mixedresidential4.02.56881,194
Hotcommercial––2,56297
Hotresidential4.03.52,046155
Part-load test points (23 values)
c__t1_min_cap_power_rated
555 W
h__h1_min_cap_power_rated
568 W
h__h2_ext_cap_power_rated
2746 W
c__t1_half_cap_power_rated
960 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
840 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3120 W
h__h2_ext_cap_heat_cap_rated
7480 W
h__h1_half_cap_heat_cap_rated
4550 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
427 W
c__t1_min_cap_cooling_cap_rated
2850 W
c__low_temp_half_cap_power_rated
746 W
c__t1_half_cap_cooling_cap_rated
4710 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3250 W
c__low_temp_half_cap_cooling_cap_rated
5030 W

New Zealand E3 registration details

Registration number
AAC8814
GEMS registration id
169135
Status
approved, available (self-reported)
Registration expires
29 April 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.