c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
3,534 kWh
550 cooling + 2,984 heating
Estimated running cost
$1,166 / year
$97 / month Β· $11,662 over 10 years
Capacity
9 kW cooling
9 kW heating

20% less electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 95% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 53% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-100PZ3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,534$1,166$11,662
Mixed zone 1,976$652$6,521
Hot zone 2,571$848$8,484

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Kogan KASSSAC80H*8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Carrier 38QAG080N8/42QAG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112

Heat pumps similar to the Panasonic U-100PZ3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Rinnai HONRTX90/HINRTX909.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Midea MFAB-90WD/MFAB-90ND9.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Rinnai HSNRTX909.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HC9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling3,874 kWh/yr4$1,278

Compare U-100PZ3R5/S-100PK3R with another model

Panasonic U-100PZ3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.00 kW
Cooling power input
2.59 kW
Rated heating capacity (7 Β°C)
9.00 kW
Heating power input
2.29 kW
EER, full load (tested)
3.48
COP, full load (tested)
3.97
Rated AEER
3.39
Rated ACOP
3.82
Standby power (PIA)
19.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1120 Γ— 302 Γ— 236 mm
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZ3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,091946
Coldresidential2.52.05502,984
Mixedcommercial––1,390502
Mixedresidential2.53.08511,125
Hotcommercial––3,094128
Hotresidential3.03.52,381190
Part-load test points (22 values)
h__h1_min_cap_power_rated
570 W
h__h2_ext_cap_power_rated
3750 W
c__t1_half_cap_power_rated
1010 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
820 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3180 W
h__h2_ext_cap_heat_cap_rated
9500 W
h__h1_half_cap_heat_cap_rated
4500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
500 W
c__low_temp_half_cap_power_rated
850 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
4500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3100 W
c__low_temp_half_cap_cooling_cap_rated
5000 W

New Zealand E3 registration details

Registration number
AAC9612
GEMS registration id
174309
Status
approved, available (self-reported)
Registration expires
15 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.