c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
12,222 kWh
1,694 cooling + 10,528 heating
Estimated running cost
$4,033 / year
$336 / month Β· $40,333 over 10 years
Capacity
22 kW cooling
24.5 kW heating

11% more electricity than the median of 37 comparable 20 kW reverse cycle ducted split system registrations (11,029 kWh a year) in the cold zone. Uses less than 11% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 11% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MOUU-220HD1N1-R running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 12,222$4,033$40,333
Mixed zone 6,523$2,153$21,526
Hot zone 8,233$2,717$27,169

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 22 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAS200DY1 / FDYA200AV122.4 kW heating20 kW cooling9,309 kWh/yr2.5$3,072
Haier 1U200S5SA2FB / AD200S5SH2FA22.4 kW heating20 kW cooling9,384 kWh/yr2.5$3,097
Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling9,482 kWh/yr3$3,129
Panasonic U-200PZH3R8 / S-200PE4R22.4 kW heating20 kW cooling9,498 kWh/yr3$3,134
Actron Air CRS20AT / EVA20AS22 kW heating19.8 kW cooling9,691 kWh/yr2.5$3,198

Heat pumps similar to the Midea MOUU-220HD1N1-R

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 1U250S5SA2FB / AD250S5SH2FA25 kW heating22 kW cooling11,034 kWh/yr2.5$3,641
Toshiba RAV-GM2803AT8P-A / RAV-GM2801DTP-A27 kW heating22 kW cooling14,569 kWh/yr2$4,808
Actron Air CRV22BT / EVV22BS23 kW heating22 kW cooling9,879 kWh/yr3$3,260
Actron Air CRV22BT / EAA22BS & EFV22BS23 kW heating22 kW cooling9,879 kWh/yr3$3,260
Fujitsu AOTH90KRTA/ARTH90KHTA25 kW heating22.4 kW cooling12,261 kWh/yr2$4,046
Panasonic U-224PZH3R8 / S-224PE4R25 kW heating22.4 kW cooling10,967 kWh/yr2.5$3,619
APAC S023OVR3SA / S023ILR1SA-FR22.7 kW heating22.4 kW cooling11,916 kWh/yr1.5$3,932
APAC S023OVR3SA / S023IVR3SA-TR22.7 kW heating22.4 kW cooling11,916 kWh/yr1.5$3,932

Compare MOUU-220HD1N1-R/MHU-220HAN1 with another model

Midea MOUU-220HD1N1-R specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
22.00 kW
Cooling power input
6.99 kW
Rated heating capacity (7 Β°C)
24.50 kW
Heating power input
7.20 kW
EER, full load (tested)
3.11
COP, full load (tested)
3.31
Rated AEER
3.11
Rated ACOP
3.37
Standby power (PIA)
23.2 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
81 dB(A)
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MOUU-220HD1N1-R zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,1133,365
Coldresidential2.01.51,69410,528
Mixedcommercial––4,9681,764
Mixedresidential1.51.52,6103,913
Hotcommercial––10,600386
Hotresidential2.02.07,637596
Part-load test points (23 values)
c__t1_min_cap_power_rated
2400 W
h__h1_min_cap_power_rated
2060 W
h__h2_ext_cap_power_rated
8450 W
c__t1_half_cap_power_rated
2820 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
3200 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
8050 W
h__h2_ext_cap_heat_cap_rated
20500 W
h__h1_half_cap_heat_cap_rated
12900 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
2400 W
c__t1_min_cap_cooling_cap_rated
9580 W
c__low_temp_half_cap_power_rated
2700 W
c__t1_half_cap_cooling_cap_rated
11000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
10000 W
c__low_temp_half_cap_cooling_cap_rated
11500 W

New Zealand E3 registration details

Registration number
AAC9509
GEMS registration id
173741
Status
approved, available (self-reported)
Registration expires
19 October 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.