New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Actron Air CRV22BT / EVV22BS Heat Pump
Actron Air CRV22BT / EVV22BS is a 22 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8794).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 9,879 kWh
- 1,336 cooling + 8,543 heating
- Estimated running cost
- $3,260 / year
- $272 / month Β· $32,601 over 10 years
- Capacity
- 22 kW cooling
- 23 kW heating
10% less electricity than the median of 37 comparable 20 kW reverse cycle ducted split system registrations (11,029 kWh a year) in the cold zone. Uses less than 76% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 14% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Actron Air CRV22BT running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 9,879 | $3,260 | $32,601 |
| Mixed zone | 5,232 | $1,727 | $17,266 |
| Hot zone | 6,577 | $2,170 | $21,704 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 22 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAS200DY1 / FDYA200AV122.4 kW heating20 kW cooling9,309 kWh/yr | 2.5 | $3,072 | |
| Haier 1U200S5SA2FB / AD200S5SH2FA22.4 kW heating20 kW cooling9,384 kWh/yr | 2.5 | $3,097 | |
| Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling9,482 kWh/yr | 3 | $3,129 | |
| Panasonic U-200PZH3R8 / S-200PE4R22.4 kW heating20 kW cooling9,498 kWh/yr | 3 | $3,134 |
Heat pumps similar to the Actron Air CRV22BT
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea UCMI220OC-3PH/DUCMI220IHC-3PH24.5 kW heating22 kW cooling12,222 kWh/yr | 2 | $4,033 | |
| Midea MOUU-220HD1N1-R/MHU-220HAN124.5 kW heating22 kW cooling12,222 kWh/yr | 2 | $4,033 | |
| Toshiba RAV-GM2803AT8P-A / RAV-GM2801DTP-A27 kW heating22 kW cooling14,569 kWh/yr | 2 | $4,808 | |
| Haier 1U250S5SA2FB / AD250S5SH2FA25 kW heating22 kW cooling11,034 kWh/yr | 2.5 | $3,641 | |
| APAC S023OVR3SA / S023ILR1SA-FR22.7 kW heating22.4 kW cooling11,916 kWh/yr | 1.5 | $3,932 | |
| Fujitsu AOTH90KRTA/ARTH90KHTA25 kW heating22.4 kW cooling12,261 kWh/yr | 2 | $4,046 | |
| APAC S023OVR3SA / S023IVR3SA-TR22.7 kW heating22.4 kW cooling11,916 kWh/yr | 1.5 | $3,932 | |
| Panasonic U-224PZH3R8 / S-224PE4R25 kW heating22.4 kW cooling10,967 kWh/yr | 2.5 | $3,619 |
Compare CRV22BT / EVV22BS with another model
Actron Air CRV22BT specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 22.00 kW
- Cooling power input
- 6.61 kW
- Rated heating capacity (7 Β°C)
- 23.00 kW
- Heating power input
- 6.25 kW
- EER, full load (tested)
- 3.27
- COP, full load (tested)
- 3.65
- Rated AEER
- 3.31
- Rated ACOP
- 3.65
- Standby power (PIA)
- 13.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Australia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air CRV22BT zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 2,509 | 2,693 |
| Coldresidential | residential | 3.0 | 2.0 | 1,336 | 8,543 |
| Mixedcommercial | commercial | β | β | 3,392 | 1,386 |
| Mixedresidential | residential | 2.5 | 2.5 | 2,099 | 3,133 |
| Hotcommercial | commercial | β | β | 7,825 | 292 |
| Hotresidential | residential | 3.0 | 3.0 | 6,119 | 458 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 6590 W
- c__t1_half_cap_power_rated
- 2886 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 2317 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 19312 W
- h__h1_half_cap_heat_cap_rated
- 11455 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 2245 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 11531 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 11990 W
Other model numbers on registration AAC8794
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC8794
- GEMS registration id
- 168458
- Status
- approved, available (self-reported)
- Registration expires
- 15 April 2030
- Registered for sale in
- Australia, New Zealand
- Family
- CRV22BT / EVV22BS
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.