c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
12,222 kWh
1,694 cooling + 10,528 heating
Estimated running cost
$4,033 / year
$336 / month Β· $40,333 over 10 years
Capacity
22 kW cooling
24.5 kW heating

11% more electricity than the median of 37 comparable 20 kW reverse cycle ducted split system registrations (11,029 kWh a year) in the cold zone. Uses less than 11% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 11% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 12,222$4,033$40,333
Mixed zone 6,523$2,153$21,526
Hot zone 8,233$2,717$27,169

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 22 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAS200DY1 / FDYA200AV122.4 kW heating20 kW cooling9,309 kWh/yr2.5$3,072
Haier 1U200S5SA2FB / AD200S5SH2FA22.4 kW heating20 kW cooling9,384 kWh/yr2.5$3,097
Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling9,482 kWh/yr3$3,129
Panasonic U-200PZH3R8 / S-200PE4R22.4 kW heating20 kW cooling9,498 kWh/yr3$3,134
Actron Air CRS20AT / EVA20AS22 kW heating19.8 kW cooling9,691 kWh/yr2.5$3,198

Heat pumps similar to the Midea

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 1U250S5SA2FB / AD250S5SH2FA25 kW heating22 kW cooling11,034 kWh/yr2.5$3,641
Toshiba RAV-GM2803AT8P-A / RAV-GM2801DTP-A27 kW heating22 kW cooling14,569 kWh/yr2$4,808
Actron Air CRV22BT / EVV22BS23 kW heating22 kW cooling9,879 kWh/yr3$3,260
Actron Air CRV22BT / EAA22BS & EFV22BS23 kW heating22 kW cooling9,879 kWh/yr3$3,260
Fujitsu AOTH90KRTA/ARTH90KHTA25 kW heating22.4 kW cooling12,261 kWh/yr2$4,046
Panasonic U-224PZH3R8 / S-224PE4R25 kW heating22.4 kW cooling10,967 kWh/yr2.5$3,619
APAC S023OVR3SA / S023ILR1SA-FR22.7 kW heating22.4 kW cooling11,916 kWh/yr1.5$3,932
APAC S023OVR3SA / S023IVR3SA-TR22.7 kW heating22.4 kW cooling11,916 kWh/yr1.5$3,932

Compare UCMI220OC-3PH/DUCMI220IHC-3PH with another model

Midea specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
22.00 kW
Cooling power input
6.99 kW
Rated heating capacity (7 Β°C)
24.50 kW
Heating power input
7.20 kW
EER, full load (tested)
3.11
COP, full load (tested)
3.31
Rated AEER
3.11
Rated ACOP
3.37
Standby power (PIA)
23.2 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
81 dB(A)
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,1133,365
Coldresidential2.01.51,69410,528
Mixedcommercial––4,9681,764
Mixedresidential1.51.52,6103,913
Hotcommercial––10,600386
Hotresidential2.02.07,637596
Part-load test points (23 values)
c__t1_min_cap_power_rated
2400 W
h__h1_min_cap_power_rated
2060 W
h__h2_ext_cap_power_rated
8450 W
c__t1_half_cap_power_rated
2820 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
3200 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
8050 W
h__h2_ext_cap_heat_cap_rated
20500 W
h__h1_half_cap_heat_cap_rated
12900 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
2400 W
c__t1_min_cap_cooling_cap_rated
9580 W
c__low_temp_half_cap_power_rated
2700 W
c__t1_half_cap_cooling_cap_rated
11000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
10000 W
c__low_temp_half_cap_cooling_cap_rated
11500 W

New Zealand E3 registration details

Registration number
AAC9516
GEMS registration id
173784
Status
approved, available (self-reported)
Registration expires
22 October 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.