New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Mitsubishi Electric PUZ-M125VKA2-A/PEA-M125GAA Heat Pump
Mitsubishi Electric PUZ-M125VKA2-A/PEA-M125GAA is a 12 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9186).
- Energy rating (cooling)
- 2
- Heating: 1.5
- Annual electricity use
- 6,667 kWh
- 857 cooling + 5,810 heating
- Estimated running cost
- $2,200 / year
- $183 / month Β· $22,001 over 10 years
- Capacity
- 12 kW cooling
- 14 kW heating
9% more electricity than the median of 146 comparable 12.5 kW reverse cycle ducted split system registrations (6,125 kWh a year) in the cold zone. Uses less than 23% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 26% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Mitsubishi Electric PUZ-M125VKA2-A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 6,667 | $2,200 | $22,001 |
| Mixed zone | 3,444 | $1,137 | $11,365 |
| Hot zone | 4,120 | $1,360 | $13,596 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 12 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr | 4.5 | $1,440 | |
| Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr | 3 | $1,471 | |
| Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr | 3 | $1,565 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr | 4 | $1,576 | |
| Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr | 3.5 | $1,583 |
Heat pumps similar to the Mitsubishi Electric PUZ-M125VKA2-A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr | 4.5 | $1,440 | |
| Samsung Electronics AC120TXAPKG/SA / AC120TNHDKG/SA14 kW heating12 kW cooling5,952 kWh/yr | 3 | $1,964 | |
| Samsung Electronics AC120TXAPNG/SA / AC120TNHDKG/SA14 kW heating12 kW cooling5,952 kWh/yr | 3 | $1,964 | |
| Haier 1U125S2SP5FA / AD125S2SM7FA14 kW heating12 kW cooling7,120 kWh/yr | 2 | $2,350 | |
| Panasonic U-125PZ4R5 / S-1014PF3E12.1 kW heating12.1 kW cooling5,030 kWh/yr | 3 | $1,660 | |
| Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr | 3 | $1,471 | |
| Mitsubishi Heavy Industries FDC125VNP-W / FDUA125VH12.1 kW heating12.1 kW cooling6,773 kWh/yr | 2.5 | $2,235 | |
| Mitsubishi Heavy Industries FDCA125VNP-W / FDUA125VH12.1 kW heating12.1 kW cooling6,773 kWh/yr | 2.5 | $2,235 |
Compare PUZ-M125VKA2-A/PEA-M125GAA with another model
Mitsubishi Electric PUZ-M125VKA2-A specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 12.00 kW
- Cooling power input
- 3.81 kW
- Rated heating capacity (7 Β°C)
- 14.00 kW
- Heating power input
- 3.54 kW
- EER, full load (tested)
- 3.19
- COP, full load (tested)
- 4.06
- Rated AEER
- 3.09
- Rated ACOP
- 3.87
- Standby power (PIA)
- 22.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Electric PUZ-M125VKA2-A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,833 | 1,827 |
| Coldresidential | residential | 2.0 | 1.5 | 857 | 5,810 |
| Mixedcommercial | commercial | β | β | 2,296 | 956 |
| Mixedresidential | residential | 2.0 | 2.0 | 1,324 | 2,120 |
| Hotcommercial | commercial | β | β | 5,053 | 224 |
| Hotresidential | residential | 2.5 | 2.5 | 3,779 | 341 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 4230 W
- c__t1_half_cap_power_rated
- 1440 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1570 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 10900 W
- h__h1_half_cap_heat_cap_rated
- 7000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 6000 W
- c__low_temp_have_half_cap_results
- No
New Zealand E3 registration details
- Registration number
- AAC9186
- GEMS registration id
- 171753
- Status
- approved, available (self-reported)
- Registration expires
- 5 August 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.