New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Mitsubishi Electric PUZ-ZM100YKA3-A / PEAD-M100JAA2 Heat Pump
Mitsubishi Electric PUZ-ZM100YKA3-A / PEAD-M100JAA2 is a 10 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7841).
- Energy rating (cooling)
- 2
- Heating: 2
- Annual electricity use
- 4,609 kWh
- 657 cooling + 3,952 heating
- Estimated running cost
- $1,521 / year
- $127 / month Β· $15,210 over 10 years
- Capacity
- 10 kW cooling
- 11.2 kW heating
3% less electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 61% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 42% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Mitsubishi Electric running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,609 | $1,521 | $15,210 |
| Mixed zone | 2,496 | $824 | $8,237 |
| Hot zone | 2,981 | $984 | $9,837 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr | 4 | $1,208 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr | 3.5 | $1,217 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr | 5 | $1,225 |
Heat pumps similar to the Mitsubishi Electric
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr | 4.5 | $1,395 | |
| Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling3,866 kWh/yr | 2.5 | $1,276 | |
| Toshiba RAV-GM1101ATP-A/RAV-GM1101DTP-A111.2 kW heating10 kW cooling4,559 kWh/yr | 2.5 | $1,504 | |
| Daikin RZAV100FV1 / FBA100BVMA12 kW heating10 kW cooling4,302 kWh/yr | 3.5 | $1,420 | |
| Pioneer International VPC-36A1/VPE-36A110 kW heating10 kW cooling4,523 kWh/yr | 3.5 | $1,493 | |
| Pioneer International VPC-36A1/CPE-36A110 kW heating10 kW cooling4,523 kWh/yr | 3.5 | $1,493 | |
| Daikin RZAV100CV1 / FBA100BVMA11.2 kW heating10 kW cooling4,295 kWh/yr | 3 | $1,417 | |
| Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling3,866 kWh/yr | 2.5 | $1,276 |
Compare PUZ-ZM100YKA3-A / PEAD-M100JAA2 with another model
Mitsubishi Electric specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- 2.67 kW
- Rated heating capacity (7 Β°C)
- 11.20 kW
- Heating power input
- 2.80 kW
- EER, full load (tested)
- 4.14
- COP, full load (tested)
- 4.52
- Rated AEER
- 3.59
- Rated ACOP
- 3.84
- Standby power (PIA)
- 33.6 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1400 Γ 250 Γ 732 mm
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Electric zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,331 | 1,289 |
| Coldresidential | residential | 2.0 | 2.0 | 657 | 3,952 |
| Mixedcommercial | commercial | β | β | 1,654 | 692 |
| Mixedresidential | residential | 2.0 | 2.5 | 995 | 1,501 |
| Hotcommercial | commercial | β | β | 3,575 | 191 |
| Hotresidential | residential | 3.0 | 3.0 | 2,702 | 279 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 4120 W
- c__t1_half_cap_power_rated
- 1000 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1070 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 10700 W
- h__h1_half_cap_heat_cap_rated
- 5600 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- No
Other model numbers on registration AAC7841
Registered together and sharing the same test results. Usually variants of the same unit.
- Mitsubishi Electric PUZ-ZM100YKA3-A / PEAD-M100JAA
- Mitsubishi Electric PUZ-ZM100YKA3-A / PEAD-M100JAAD2
- Mitsubishi Electric PUZ-ZM100YKA2-A / PEAD-M100JAA
- Mitsubishi Electric PUZ-ZM100YKA3-A / PEAD-M100JAA(D) Series
- Mitsubishi Electric PUZ-ZM100YKA3-A / PEAD-M100JAAD
- Mitsubishi Electric PUZ-ZM100YKA2-A / PEAD-M100JAAD
New Zealand E3 registration details
- Registration number
- AAC7841
- GEMS registration id
- 157318
- Status
- approved, available (self-reported)
- Registration expires
- 24 October 2028
- Registered for sale in
- Australia, New Zealand
- Family
- PUZ-ZM100YKA3-A / PEAD-M100JAA(D) Series
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.