c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
6,552 kWh
874 cooling + 5,678 heating
Estimated running cost
$2,162 / year
$180 / month Β· $21,622 over 10 years
Capacity
14 kW cooling
16 kW heating

2% less electricity than the median of 66 comparable 14 kW reverse cycle split system registrations (6,658 kWh a year) in the cold zone. Uses less than 61% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 28% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Heavy Industries FDC(A)140VSX-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,552$2,162$21,622
Mixed zone 3,449$1,138$11,382
Hot zone 4,281$1,413$14,127

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Mitsubishi Heavy Industries FDC(A)140VSX-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUZ-ZM140VKA-A/PCA-M140KA16 kW heating13.5 kW cooling6,597 kWh/yr2$2,177
Mitsubishi Electric PUZ-ZM140VKA-A/PCA-M140KA Series16 kW heating13.5 kW cooling6,597 kWh/yr2$2,177
Panasonic U-140PZ4R8 / S-1014PU3E14 kW heating14 kW cooling5,410 kWh/yr3$1,785
Panasonic U-140PZ4R5 / S-1014PU3E14 kW heating14 kW cooling5,410 kWh/yr3$1,785
Daikin RZAV140F2V1 / FCA140CVMA16.5 kW heating14 kW cooling5,814 kWh/yr4$1,919
Daikin RZAV140FY1 / FCA140CVMA16.5 kW heating14 kW cooling5,812 kWh/yr4$1,918
Mdv C-UV-140N8-QC3W / CSV-140N8-QC3W14.5 kW heating14 kW cooling5,771 kWh/yr4$1,904
Kaden KDI48 / KCI4814.5 kW heating14 kW cooling5,771 kWh/yr4$1,904

Compare FDC(A)140VSX-W / FDE140VH with another model

Mitsubishi Heavy Industries FDC(A)140VSX-W specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.08 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.41 kW
EER, full load (tested)
3.50
COP, full load (tested)
3.90
Rated AEER
3.39
Rated ACOP
3.59
Standby power (PIA)
13.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
65 dB(A)
Outdoor sound power
69 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Heavy Industries FDC(A)140VSX-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9071,777
Coldresidential2.52.08745,678
Mixedcommercial––2,399916
Mixedresidential2.52.51,3642,085
Hotcommercial––5,328198
Hotresidential3.03.03,973308
Part-load test points (16 values)
h__h2_ext_cap_power_rated
6120 W
c__t1_half_cap_power_rated
1520 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1500 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
15500 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC9805

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC9805
GEMS registration id
175131
Status
approved, available (self-reported)
Registration expires
29 January 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
FDC(A)140VSX-W / FDE140VH
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.