c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
960 kWh
100 cooling + 860 heating
Estimated running cost
$317 / year
$26 / month Β· $3,168 over 10 years
Capacity
2 kW cooling
2.8 kW heating

16% more electricity than the median of 63 comparable 2 kW reverse cycle split system registrations (829 kWh a year) in the cold zone. Uses less than 22% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 89% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic CU-Z20AKR running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 960$317$3,168
Mixed zone 479$158$1,581
Hot zone 486$160$1,604

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling708 kWh/yr5.5$234
Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling718 kWh/yr5.5$237
Kaden KSI062.3 kW heating2 kW cooling718 kWh/yr5.5$237
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling718 kWh/yr5.5$237
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239

Heat pumps similar to the Panasonic CU-Z20AKR

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MFAB-20WD/MFAB-20ND2.4 kW heating2 kW cooling778 kWh/yr5$257
Comfee CASG-XG20B/CASN-XG20B2.4 kW heating2 kW cooling778 kWh/yr5$257
Midea MFAG20VB-W/MFAG20VB-N2.4 kW heating2 kW cooling778 kWh/yr5$257
Kaden KSI-2.02.4 kW heating2 kW cooling778 kWh/yr5$257
Rinnai HSNRTX202.4 kW heating2 kW cooling778 kWh/yr5$257
Carrier 38QAF020N8/42QAF020N82.4 kW heating2 kW cooling778 kWh/yr5$257
Carrier 42QHG020N8PB/38QUH020N8PB2.4 kW heating2 kW cooling778 kWh/yr5$257

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic CU-Z20DKR / CS-Z20DKRW2.8 kW heating2 kW cooling960 kWh/yr3.5$317

Compare CU-Z20AKR / CS-Z20AKRW with another model

Panasonic CU-Z20AKR specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.05 kW
Cooling power input
0.45 kW
Rated heating capacity (7 Β°C)
2.80 kW
Heating power input
0.60 kW
EER, full load (tested)
4.63
COP, full load (tested)
4.43
Rated AEER
4.47
Rated ACOP
4.60
Standby power (PIA)
2.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
54 dB(A)
Outdoor sound power
61 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic CU-Z20AKR zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––177280
Coldresidential3.52.5100860
Mixedcommercial––240148
Mixedresidential3.53.0154325
Hotcommercial––54334
Hotresidential4.53.543452
Part-load test points (23 values)
c__t1_min_cap_power_rated
200 W
h__h2_ext_cap_power_rated
950 W
c__t1_half_cap_power_rated
230 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
250 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2850 W
h__h1_half_cap_heat_cap_rated
1400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
155 W
c__t1_min_cap_cooling_cap_rated
950 W
c__low_temp_full_cap_power_rated
411.3 W
c__low_temp_half_cap_power_rated
170 W
c__t1_half_cap_cooling_cap_rated
1025 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1050 W
c__low_temp_full_cap_cooling_cap_rated
2207.85 W
c__low_temp_half_cap_cooling_cap_rated
1150 W

New Zealand E3 registration details

Registration number
AAC8201
GEMS registration id
160524
Status
approved, available (self-reported)
Registration expires
2 May 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8