New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Panasonic U-100PZ4R5 / S-1014PF3E Heat Pump
Panasonic U-100PZ4R5 / S-1014PF3E is a 9.5 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9360).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 3,699 kWh
- 536 cooling + 3,163 heating
- Estimated running cost
- $1,221 / year
- $102 / month Β· $12,207 over 10 years
- Capacity
- 9.5 kW cooling
- 9.5 kW heating
22% less electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 96% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 50% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Panasonic U-100PZ4R5 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,699 | $1,221 | $12,207 |
| Mixed zone | 2,011 | $664 | $6,636 |
| Hot zone | 2,578 | $851 | $8,507 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps similar to the Panasonic U-100PZ4R5
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| LG UU100WR2 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling5,594 kWh/yr | 2 | $1,846 | |
| LG UU100WR3 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling4,493 kWh/yr | 2.5 | $1,483 | |
| Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr | 4.5 | $1,395 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr | 3.5 | $1,217 | |
| Carrier 38QSP090N8/42QSP090N810.5 kW heating9 kW cooling3,834 kWh/yr | 3.5 | $1,265 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr | 4 | $1,208 |
Other Panasonic models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 |
Compare U-100PZ4R5 / S-1014PF3E with another model
Panasonic U-100PZ4R5 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 9.50 kW
- Cooling power input
- 2.66 kW
- Rated heating capacity (7 Β°C)
- 9.50 kW
- Heating power input
- 2.32 kW
- EER, full load (tested)
- 3.54
- COP, full load (tested)
- 4.00
- Rated AEER
- 3.50
- Rated ACOP
- 4.01
- Standby power (PIA)
- 15.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Malaysia, China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-100PZ4R5 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,063 | 981 |
| Coldresidential | residential | 3.0 | 2.0 | 536 | 3,163 |
| Mixedcommercial | commercial | β | β | 1,357 | 509 |
| Mixedresidential | residential | 3.0 | 3.0 | 834 | 1,177 |
| Hotcommercial | commercial | β | β | 3,135 | 122 |
| Hotresidential | residential | 3.5 | 3.5 | 2,391 | 187 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 440 W
- h__h2_ext_cap_power_rated
- 3150 W
- c__t1_half_cap_power_rated
- 930 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 920 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2500 W
- h__h2_ext_cap_heat_cap_rated
- 9000 W
- h__h1_half_cap_heat_cap_rated
- 4750 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 410 W
- c__low_temp_half_cap_power_rated
- 800 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 4750 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2900 W
- c__low_temp_half_cap_cooling_cap_rated
- 5000 W
New Zealand E3 registration details
- Registration number
- AAC9360
- GEMS registration id
- 171990
- Status
- approved, available (self-reported)
- Registration expires
- 31 August 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 10
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.