c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
3,600 kWh
539 cooling + 3,061 heating
Estimated running cost
$1,188 / year
$99 / month Β· $11,880 over 10 years
Capacity
9 kW cooling
9 kW heating

19% less electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 92% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 52% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-100PZ4R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,600$1,188$11,880
Mixed zone 1,989$656$6,564
Hot zone 2,573$849$8,491

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Kogan KASSSAC80H*8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Kogan KASSSAC80HF8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Carrier 38QAG080N8/42QAG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112

Heat pumps similar to the Panasonic U-100PZ4R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Rinnai HONRTX90/HINRTX909.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Midea MFAB-90WD/MFAB-90ND9.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Rinnai HSNRTX909.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HC9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling3,874 kWh/yr4$1,278

Compare U-100PZ4R8 / S-100PK4R with another model

Panasonic U-100PZ4R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.00 kW
Cooling power input
2.65 kW
Rated heating capacity (7 Β°C)
9.00 kW
Heating power input
2.34 kW
EER, full load (tested)
3.34
COP, full load (tested)
3.97
Rated AEER
3.33
Rated ACOP
3.76
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZ4R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,079966
Coldresidential2.52.05393,061
Mixedcommercial––1,382508
Mixedresidential2.52.58421,147
Hotcommercial––3,110123
Hotresidential3.03.52,388185
Part-load test points (22 values)
h__h1_min_cap_power_rated
560 W
h__h2_ext_cap_power_rated
4350 W
c__t1_half_cap_power_rated
1000 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
850 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3000 W
h__h2_ext_cap_heat_cap_rated
10000 W
h__h1_half_cap_heat_cap_rated
4500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
430 W
c__low_temp_half_cap_power_rated
850 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
4500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2650 W
c__low_temp_half_cap_cooling_cap_rated
5000 W

New Zealand E3 registration details

Registration number
AAC9122
GEMS registration id
170852
Status
approved, available (self-reported)
Registration expires
22 July 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9