New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Panasonic U-100PZ4R8 / S-100PK4R Heat Pump
Panasonic U-100PZ4R8 / S-100PK4R is a 9 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9122).
- Energy rating (cooling)
- 2.5
- Heating: 2
- Annual electricity use
- 3,600 kWh
- 539 cooling + 3,061 heating
- Estimated running cost
- $1,188 / year
- $99 / month Β· $11,880 over 10 years
- Capacity
- 9 kW cooling
- 9 kW heating
19% less electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 92% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 52% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Panasonic U-100PZ4R8 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,600 | $1,188 | $11,880 |
| Mixed zone | 1,989 | $656 | $6,564 |
| Hot zone | 2,573 | $849 | $8,491 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 9 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Kogan KASSSAC80H*8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Kogan KASSSAC80HF8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Carrier 38QAG080N8/42QAG080N88.2 kW heating8 kW cooling3,371 kWh/yr | 3.5 | $1,112 | |
| Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr | 3.5 | $1,112 |
Heat pumps similar to the Panasonic U-100PZ4R8
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling3,874 kWh/yr | 4 | $1,278 | |
| Rinnai HONRTX90/HINRTX909.5 kW heating9 kW cooling3,874 kWh/yr | 4 | $1,278 | |
| Midea MFAB-90WD/MFAB-90ND9.5 kW heating9 kW cooling3,874 kWh/yr | 4 | $1,278 | |
| Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling3,874 kWh/yr | 4 | $1,278 | |
| Rinnai HSNRTX909.5 kW heating9 kW cooling3,874 kWh/yr | 4 | $1,278 | |
| Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Kogan KASSSAC90HC9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling3,874 kWh/yr | 4 | $1,278 |
Compare U-100PZ4R8 / S-100PK4R with another model
Panasonic U-100PZ4R8 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 9.00 kW
- Cooling power input
- 2.65 kW
- Rated heating capacity (7 Β°C)
- 9.00 kW
- Heating power input
- 2.34 kW
- EER, full load (tested)
- 3.34
- COP, full load (tested)
- 3.97
- Rated AEER
- 3.33
- Rated ACOP
- 3.76
- Standby power (PIA)
- 15.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-100PZ4R8 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,079 | 966 |
| Coldresidential | residential | 2.5 | 2.0 | 539 | 3,061 |
| Mixedcommercial | commercial | β | β | 1,382 | 508 |
| Mixedresidential | residential | 2.5 | 2.5 | 842 | 1,147 |
| Hotcommercial | commercial | β | β | 3,110 | 123 |
| Hotresidential | residential | 3.0 | 3.5 | 2,388 | 185 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 560 W
- h__h2_ext_cap_power_rated
- 4350 W
- c__t1_half_cap_power_rated
- 1000 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 850 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3000 W
- h__h2_ext_cap_heat_cap_rated
- 10000 W
- h__h1_half_cap_heat_cap_rated
- 4500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 430 W
- c__low_temp_half_cap_power_rated
- 850 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 4500 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2650 W
- c__low_temp_half_cap_cooling_cap_rated
- 5000 W
New Zealand E3 registration details
- Registration number
- AAC9122
- GEMS registration id
- 170852
- Status
- approved, available (self-reported)
- Registration expires
- 22 July 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.