c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
5,318 kWh
642 cooling + 4,676 heating
Estimated running cost
$1,755 / year
$146 / month Β· $17,549 over 10 years
Capacity
12.1 kW cooling
13.5 kW heating

13% less electricity than the median of 143 comparable 12.5 kW reverse cycle ducted split system registrations (6,119 kWh a year) in the cold zone. Uses less than 84% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 37% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-125PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,318$1,755$17,549
Mixed zone 2,745$906$9,059
Hot zone 3,164$1,044$10,441

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr3.5$1,583

Heat pumps similar to the Panasonic U-125PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Samsung Electronics AC120HCADKG/SA / AC120HEHPKG/SA13 kW heating12.1 kW cooling6,889 kWh/yr2.5$2,273
Mitsubishi Heavy Industries FDCA125VNP-W / FDUA125VH12.1 kW heating12.1 kW cooling6,773 kWh/yr2.5$2,235
Samsung Electronics AC120HCADNG/SA / AC120HEHPKG/SA13 kW heating12.1 kW cooling6,889 kWh/yr2.5$2,273
Mitsubishi Heavy Industries FDC125VNP-W / FDUA125VH12.1 kW heating12.1 kW cooling6,773 kWh/yr2.5$2,235
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Haier 1U125S2SP5FA / AD125S2SM7FA14 kW heating12 kW cooling7,120 kWh/yr2$2,350
Mitsubishi Electric PUZ-M125VKA2-A/PEA-M125HAA214 kW heating12 kW cooling6,455 kWh/yr2$2,130
Mitsubishi Electric PUZ-M125VKA2-A/PEA-M125HAA14 kW heating12 kW cooling6,455 kWh/yr2$2,130

Compare U-125PZH3R5/S-1014PF3E with another model

Panasonic U-125PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.10 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
13.50 kW
Heating power input
–
EER, full load (tested)
3.66
COP, full load (tested)
3.70
Rated AEER
3.53
Rated ACOP
3.42
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-125PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,2551,412
Coldresidential3.52.06424,676
Mixedcommercial––1,622725
Mixedresidential3.02.51,0101,735
Hotcommercial––3,783161
Hotresidential3.53.52,914250
Part-load test points (22 values)
h__h1_min_cap_power_rated
570 W
h__h2_ext_cap_power_rated
5380 W
c__t1_half_cap_power_rated
1170 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1300 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3250 W
h__h2_ext_cap_heat_cap_rated
14000 W
h__h1_half_cap_heat_cap_rated
6750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
465 W
c__low_temp_half_cap_power_rated
975 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
6050 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_cooling_cap_rated
6400 W

New Zealand E3 registration details

Registration number
AAC9625
GEMS registration id
–
Status
approved
Registration expires
8 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.