c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
6,613 kWh
742 cooling + 5,871 heating
Estimated running cost
$2,182 / year
$182 / month Β· $21,823 over 10 years
Capacity
13.4 kW cooling
16 kW heating

1% less electricity than the median of 66 comparable 14 kW reverse cycle split system registrations (6,658 kWh a year) in the cold zone. Uses less than 52% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 27% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-140PZH3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,613$2,182$21,823
Mixed zone 3,280$1,082$10,824
Hot zone 3,712$1,225$12,250

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Panasonic U-140PZH3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU140WR2 U30/UTN140MA NA015.5 kW heating13.4 kW cooling9,197 kWh/yr1.5$3,035
Mitsubishi Electric PUZ-ZM140VKA-A/PCA-M140KA216 kW heating13.5 kW cooling6,597 kWh/yr2$2,177
Hisense AUW-140U4RN1/ AUC-140U4RKC115 kW heating13.5 kW cooling8,256 kWh/yr2.5$2,724
Mitsubishi Electric PUZ-ZM140VKA-A/PCA-M140KA16 kW heating13.5 kW cooling6,597 kWh/yr2$2,177
Samsung Electronics AC140HCADKG/SA / AC140HE6DKG/SA16 kW heating13.6 kW cooling7,468 kWh/yr2.5$2,464
Samsung Electronics AC140TXAPKG/SA / AC140TN4PKG/SA16 kW heating13.6 kW cooling7,752 kWh/yr2.5$2,558
LG UU140WR3 U30/UTN140MA NA015.5 kW heating13.6 kW cooling7,637 kWh/yr2.5$2,520

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-140PZH3R5/S-1014PT3E16 kW heating13.4 kW cooling6,613 kWh/yr3$2,182

Compare U-140PZH3R8/S-1014PT3E with another model

Panasonic U-140PZH3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor / ceiling
Rated cooling capacity (35 Β°C)
13.40 kW
Cooling power input
4.17 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.60 kW
EER, full load (tested)
3.48
COP, full load (tested)
3.67
Rated AEER
3.17
Rated ACOP
3.44
Standby power (PIA)
17.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1590 Γ— 235 Γ— 690 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-140PZH3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,4241,740
Coldresidential3.02.07425,871
Mixedcommercial––1,857863
Mixedresidential3.02.51,1802,100
Hotcommercial––4,410189
Hotresidential3.53.53,415297
Part-load test points (22 values)
h__h1_min_cap_power_rated
560 W
h__h2_ext_cap_power_rated
6250 W
c__t1_half_cap_power_rated
1320 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1580 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3200 W
h__h2_ext_cap_heat_cap_rated
14800 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
455 W
c__low_temp_half_cap_power_rated
1100 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
6700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_cooling_cap_rated
7050 W

New Zealand E3 registration details

Registration number
AAC9787
GEMS registration id
175931
Status
approved, available (self-reported)
Registration expires
11 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.