c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
7,819 kWh
1,046 cooling + 6,773 heating
Estimated running cost
$2,580 / year
$215 / month Β· $25,803 over 10 years
Capacity
16 kW cooling
18 kW heating

2% less electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (7,959 kWh a year) in the cold zone. Uses less than 68% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 20% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-160PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,819$2,580$25,803
Mixed zone 4,183$1,380$13,804
Hot zone 5,012$1,654$16,540

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 16 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling6,561 kWh/yr2.5$2,165
Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling6,561 kWh/yr2.5$2,165
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling6,926 kWh/yr3$2,286

Heat pumps similar to the Panasonic U-160PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Tosot TFH60DEXL-S6DND7D/O / TFH60DEXL-S6DND7D/I18 kW heating16 kW cooling7,462 kWh/yr3.5$2,462
Gree GFH60DEXL-S6DND7D/O / GFH60DEXL-S6DND7D/I18 kW heating16 kW cooling7,460 kWh/yr3.5$2,462
Braemar KCHB160D1B/KDHB160D1S18 kW heating16 kW cooling7,460 kWh/yr3.5$2,462
Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA218 kW heating16 kW cooling7,459 kWh/yr3$2,461
Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA2-UF18 kW heating16 kW cooling7,459 kWh/yr3$2,461
Braemar KCHA160D1B/KDHA160D1S18 kW heating16 kW cooling7,395 kWh/yr3.5$2,440
TECO TDS-TSO160HVSWDG18 kW heating16 kW cooling7,395 kWh/yr3.5$2,440
Gree GUD160W1/NhC-S / GUD160PHS1/C-S18 kW heating16 kW cooling7,395 kWh/yr3.5$2,440

Compare U-160PZH3R5 / S-160PE3R with another model

Panasonic U-160PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
16.00 kW
Cooling power input
4.86 kW
Rated heating capacity (7 Β°C)
18.00 kW
Heating power input
5.10 kW
EER, full load (tested)
3.20
COP, full load (tested)
3.49
Rated AEER
3.24
Rated ACOP
3.47
Standby power (PIA)
23.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-160PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9712,152
Coldresidential2.51.51,0466,773
Mixedcommercial––2,5881,140
Mixedresidential2.52.01,6132,570
Hotcommercial––5,916261
Hotresidential2.52.54,612400
Part-load test points (25 values)
c__t1_min_cap_power_rated
1250 W
h__h1_min_cap_power_rated
1200 W
h__h2_ext_cap_power_rated
5920 W
c__t1_half_cap_power_rated
2250 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1980 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
5500 W
h__h2_ext_cap_heat_cap_rated
16640 W
h__h1_half_cap_heat_cap_rated
9000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
1040 W
c__t1_min_cap_cooling_cap_rated
5200 W
c__low_temp_full_cap_power_rated
4442.04 W
c__low_temp_half_cap_power_rated
1800 W
c__t1_half_cap_cooling_cap_rated
8000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
5600 W
c__low_temp_full_cap_cooling_cap_rated
17232 W
c__low_temp_half_cap_cooling_cap_rated
9000 W

New Zealand E3 registration details

Registration number
AAC7581
GEMS registration id
154658
Status
approved, available (self-reported)
Registration expires
24 June 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.