New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Panasonic U-160PZH3R8 / S-160PE3R Heat Pump
Panasonic U-160PZH3R8 / S-160PE3R is a 16 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7582).
- Energy rating (cooling)
- 2.5
- Heating: 1.5
- Annual electricity use
- 7,819 kWh
- 1,046 cooling + 6,773 heating
- Estimated running cost
- $2,580 / year
- $215 / month Β· $25,803 over 10 years
- Capacity
- 16 kW cooling
- 18 kW heating
2% less electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (7,959 kWh a year) in the cold zone. Uses less than 68% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 20% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Panasonic U-160PZH3R8 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,819 | $2,580 | $25,803 |
| Mixed zone | 4,183 | $1,380 | $13,804 |
| Hot zone | 5,012 | $1,654 | $16,540 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 16 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr | 2 | $1,483 | |
| Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling6,561 kWh/yr | 2.5 | $2,165 | |
| Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling6,561 kWh/yr | 2.5 | $2,165 | |
| Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr | 3.5 | $2,279 | |
| Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling6,926 kWh/yr | 3 | $2,286 |
Heat pumps similar to the Panasonic U-160PZH3R8
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Gree GUD160W1/NhC-S / GUD160PHS1/C-S18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 | |
| Braemar KCHB160D1B/KDHB160D1S18 kW heating16 kW cooling7,460 kWh/yr | 3.5 | $2,462 | |
| Braemar KCHA160D1B/KDHA160D1S18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 | |
| Gree GFH60DEXL-S6DND7D/O / GFH60DEXL-S6DND7D/I18 kW heating16 kW cooling7,460 kWh/yr | 3.5 | $2,462 | |
| TECO TDS-TSO160HVSWDG18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 | |
| Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA18 kW heating16 kW cooling7,459 kWh/yr | 3 | $2,461 | |
| Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA218 kW heating16 kW cooling7,459 kWh/yr | 3 | $2,461 | |
| Tosot TFH60DEXL-S6DND7D/O / TFH60DEXL-S6DND7D/I18 kW heating16 kW cooling7,462 kWh/yr | 3.5 | $2,462 |
Compare U-160PZH3R8 / S-160PE3R with another model
Panasonic U-160PZH3R8 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 16.00 kW
- Cooling power input
- 4.86 kW
- Rated heating capacity (7 Β°C)
- 18.00 kW
- Heating power input
- 5.10 kW
- EER, full load (tested)
- 3.20
- COP, full load (tested)
- 3.49
- Rated AEER
- 3.24
- Rated ACOP
- 3.47
- Standby power (PIA)
- 23.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-160PZH3R8 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,971 | 2,152 |
| Coldresidential | residential | 2.5 | 1.5 | 1,046 | 6,773 |
| Mixedcommercial | commercial | β | β | 2,588 | 1,140 |
| Mixedresidential | residential | 2.5 | 2.0 | 1,613 | 2,570 |
| Hotcommercial | commercial | β | β | 5,916 | 261 |
| Hotresidential | residential | 2.5 | 2.5 | 4,612 | 400 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 1250 W
- h__h1_min_cap_power_rated
- 1200 W
- h__h2_ext_cap_power_rated
- 5920 W
- c__t1_half_cap_power_rated
- 2250 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1980 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 5500 W
- h__h2_ext_cap_heat_cap_rated
- 16640 W
- h__h1_half_cap_heat_cap_rated
- 9000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 1040 W
- c__t1_min_cap_cooling_cap_rated
- 5200 W
- c__low_temp_full_cap_power_rated
- 4442.04 W
- c__low_temp_half_cap_power_rated
- 1800 W
- c__t1_half_cap_cooling_cap_rated
- 8000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 5600 W
- c__low_temp_full_cap_cooling_cap_rated
- 17232 W
- c__low_temp_half_cap_cooling_cap_rated
- 9000 W
New Zealand E3 registration details
- Registration number
- AAC7582
- GEMS registration id
- 154733
- Status
- approved, available (self-reported)
- Registration expires
- 25 June 2028
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.